Troubleshoot an object that is not synchronizing with Microsoft Entra ID

If an object isn't syncing as expected with Microsoft Entra ID, it can be because of several reasons. If you received an error email from Microsoft Entra ID or you see the error in Microsoft Entra Connect Health, read Troubleshooting errors during synchronization instead. But if you're troubleshooting a problem where the object isn't in Microsoft Entra ID, this article is for you. It describes how to find errors in the on-premises component Microsoft Entra Connect synchronization.

Important

For Microsoft Entra Connect deployment with version 1.1.749.0 or higher, use the troubleshooting task in the wizard to troubleshoot object syncing issues.

Synchronization process

Before we investigate syncing issues, let’s understand the Microsoft Entra Connect syncing process:

Diagram of Microsoft Entra Connect Sync process

Terminology

  • CS: Connector space, a table in a database
  • MV: Metaverse, a table in a database

Synchronization steps

The syncing process involves following steps:

  1. Import from AD: Active Directory objects are brought into the Active Directory CS.

  2. Import from Microsoft Entra ID: Microsoft Entra objects are brought into the Microsoft Entra CS.

  3. Synchronization: Inbound synchronization rules and outbound synchronization rules are run in the order of precedence number, from lower to higher. To view the synchronization rules, go to the Synchronization Rules Editor from the desktop applications. The inbound synchronization rules bring in data from CS to MV. The outbound synchronization rules move data from MV to CS.

  4. Export to AD: After syncing, objects are exported from the Active Directory CS to Active Directory.

  5. Export to Microsoft Entra ID: After syncing, objects are exported from the Microsoft Entra CS to Microsoft Entra ID.

Troubleshooting

To find the errors, look at a few different places, in the following order:

  1. The operation logs to find errors identified by the synchronization engine during import and synchronization.
  2. The connector space to find missing objects and synchronization errors.
  3. The metaverse to find data-related problems.

Start Synchronization Service Manager before you begin these steps.

Operations

The Operations tab in Synchronization Service Manager is where you should start your troubleshooting. This tab shows the results from the most recent operations.

Screenshot of Synchronization Service Manager, showing Operations tab selected

The top half of the Operations tab shows all runs in chronological order. By default, the operations log keeps information about the last seven days, but this setting can be changed with the scheduler. Look for any run that doesn't show a success status. You can change the sorting by selecting the headers.

The Status column contains the most important information and shows the most severe problem for a run. Here's a quick summary of the most common statuses in order of investigation priority (where * indicates several possible error strings).

Status Comment
stopped-* The run couldn't finish. This might happen, for example, if the remote system is down and can't be contacted.
stopped-error-limit There are more than 5,000 errors. The run was automatically stopped due to the large number of errors.
completed-*-errors The run finished, but there are errors (fewer than 5,000) that should be investigated.
completed-*-warnings The run finished, but some data isn't in the expected state. If there are errors, this message is only a symptom. Don't investigate warnings until you've addressed errors.
success No issues.

When you select a row, the bottom of the Operations tab is updated to show the details of that run. On the far-left side of this area, there might be a list titled Step #. This list appears only if there are multiple domains in your forest and each domain is represented by a step. The domain name can be found under the heading Partition. Under the Synchronization Statistics heading, you can find more information about the number of changes that were processed. Select the links to get a list of the changed objects. If there are objects with errors, those errors show up under the Synchronization Errors heading.

Errors on the Operations tab

When there are errors, Synchronization Service Manager shows both the object in error and the error itself as links that provide more information.

Screenshot of errors in Synchronization Service Manager
Start by selecting the error string. (In the preceding figure, the error string is sync-rule-error-function-triggered.) You are first presented with an overview of the object. To see the actual error, select Stack Trace. This trace provides debug-level information for the error.

Right-select the Call Stack Information box, select Select All, and then select Copy. Then copy the stack and look at the error in your favorite editor, such as Notepad.

If the error is from SyncRulesEngine, the call stack information first lists all attributes on the object. Scroll down until you see the heading InnerException =>.

Screenshot of the Synchronization Service Manager, showing error information under the heading InnerException =>

The line after the heading shows the error. In the preceding figure, the error is from a custom synchronization rule that Fabrikam created.

If the error doesn't give enough information, it's time to look at the data itself. Select the link with the object identifier and continue troubleshooting the connector space imported object.

Connector space object properties

If the Operations tab shows no errors, follow the connector space object from Active Directory to the metaverse to Microsoft Entra ID. In this path, you should find where the problem is.

Searching for an object in the CS

In Synchronization Service Manager, select Connectors, select the Active Directory Connector, and select Search Connector Space.

In the Scope box, select RDN when you want to search on the CN attribute, or select DN or anchor when you want to search on the distinguishedName attribute. Enter a value and select Search.

Screenshot of a connector space search

If you don't find the object you're looking for, it might have been filtered with domain-based filtering or OU-based filtering. To verify that the filtering is configured as expected, read Microsoft Entra Connect Sync: Configure filtering.

You can perform another useful search by selecting the Microsoft Entra Connector. In the Scope box, select Pending Import, and then select the Add check box. This search gives you all synced objects in Microsoft Entra ID that can't be associated with an on-premises object.

Screenshot of orphans in a connector space search

Those objects were created by another synchronization engine or a synchronization engine with a different filtering configuration. These orphan objects are no longer managed. Review this list and consider removing these objects by using the Microsoft Graph PowerShell cmdlets.

CS import

When you open a CS object, there are several tabs at the top. The Import tab shows the data that is staged after an import.

Screenshot of the Connector Space Object Properties window, with the Import tab selected

The Old Value column shows what currently is stored in Connect. The New Value column shows what is received from the source system and isn't applied yet. If there is an error on the object, changes are not processed.

The Synchronization Error tab is visible in the Connector Space Object Properties window only if there is a problem with the object. For more information, review how to troubleshoot sync errors on the Operations tab.

Screenshot of the Synchronization Error tab in the Connector Space Object Properties window

CS lineage

The Lineage tab in the Connector Space Object Properties window shows how the connector space object is related to the metaverse object. You can see when the connector last imported a change from the connected system and which rules applied to populate data in the metaverse.

Screenshot showing the Lineage tab in the Connector Space Object Properties window

In the preceding figure, the Action column shows an inbound synchronization rule with the action Provision. That indicates that as long as this connector space object is present, the metaverse object remains. If the list of synchronization rules instead shows an outbound synchronization rule with a Provision action, this object is deleted when the metaverse object is deleted.

Screenshot of a lineage window on the Lineage tab in the Connector Space Object Properties window

In the preceding figure, you can also see in the PasswordSync column that the inbound connector space can contribute changes to the password since one synchronization rule has the value True. This password is sent to Microsoft Entra ID through the outbound rule.

From the Lineage tab, you can get to the metaverse by selecting Metaverse Object Properties.

Preview

In the lower-left corner of the Connector Space Object Properties window is the Preview button. Select this button to open the Preview page, where you can sync a single object. This page is useful if you're troubleshooting some custom synchronization rules and want to see the effect of a change on a single object. You can select a Full sync or a Delta sync. You can also select Generate Preview, which only keeps the change in memory. Or select Commit Preview, which updates the metaverse and stages all changes to target connector spaces.

Screenshot of the Preview page, with Start Preview selected

In the preview you can inspect the object and see which rule applied for a particular attribute flow.

Screenshot of the Preview page, showing Import Attribute Flow

Log

Next to the Preview button, select the Log button to open the Log page. Here you can see the password sync status and history. For more information, see Troubleshoot password hash synchronization with Microsoft Entra Connect Sync.

Metaverse object properties

It's better to start searching from the source Active Directory connector space. But you can also start searching from the metaverse.

Searching for an object in the MV

In Synchronization Service Manager, select Metaverse Search, as in the following figure. Create a query that you know finds the user. Search for common attributes, such as accountName (sAMAccountName) and userPrincipalName. For more information, see Sync Service Manager Metaverse search.

Screenshot of Synchronization Service Manager, with the Metaverse Search tab selected

In the Search Results window, select the object.

If you didn't find the object, it hasn't reached the metaverse. Continue to search for the object in the Active Directory connector space. If you find the object in the Active Directory connector space, there could be a sync error that is blocking the object from coming to the metaverse. Or, a synchronization rule scoping filter might be applied.

Object not found in the MV

If the object is in the Active Directory CS but not present in the MV, a scoping filter is applied. To look at the scoping filter, go to the desktop application menu and select Synchronization Rules Editor. Filter the rules applicable to the object by adjusting the filter below.

Screenshot of Synchronization Rules Editor, showing an inbound synchronization rules search

View each rule in the list from above and check the Scoping filter. In the following scoping filter, if the isCriticalSystemObject value is null or FALSE or empty, it's in scope.

Screenshot of a scoping filter in an inbound synchronization rule search

Go to the CS Import attribute list and check which filter is blocking the object from moving to the MV. The Connector Space attribute list shows only non-null and non-empty attributes. For example, if isCriticalSystemObject doesn't show up in the list, the value of this attribute is null or empty.

Object not found in the Microsoft Entra CS

If the object isn't present in the connector space of Microsoft Entra ID but is present in the MV, look at the scoping filter of the outbound rules of the corresponding connector space. Determine if the object is filtered out because the MV attributes don't meet the criteria.

To look at the outbound scoping filter, select the applicable rules for the object by adjusting the following filter. View each rule and look at the corresponding MV attribute value.

Screenshot of an outbound synchronization rules search in Synchronization Rules Editor

MV Attributes

On the Attributes tab, you can see the values and which connectors contributed them.

Screenshot of the Metaverse Object Properties window, with the Attributes tab selected

If an object isn't syncing, ask the following questions about attribute states in the metaverse:

  • Is the attribute cloudFiltered present and set to True? If so, then it's filtered according to the steps in attribute-based filtering.
  • Is the attribute sourceAnchor present? If not, do you have an account-resource forest topology? If an object is identified as a linked mailbox (the attribute msExchRecipientTypeDetails has the value 2), the sourceAnchor is contributed by the forest with an enabled Active Directory account. Make sure the master account is imported and synced correctly. The master account must be listed among the connectors for the object.

MV connectors

The Connectors tab shows all connector spaces that have a representation of the object.

Screenshot of the Metaverse Object Properties window, with the Connectors tab selected

You should have a connector to:

  • Each Active Directory forest the user is represented in. This representation can include foreignSecurityPrincipals and Contact objects.
  • A connector in Microsoft Entra ID.

If you're missing the connector to Microsoft Entra ID, review the section on MV attributes to verify the criteria for provisioning to Microsoft Entra ID.

From the Connectors tab you can also go to the connector space object. Select a row and select Properties.

Next steps