ServiceDataFlowTemplate interface
Data flow template
Properties
direction | The direction of this flow. |
ports | The port(s) to which UEs will connect for this flow. You can specify zero or more ports or port ranges. If you specify one or more ports or port ranges then you must specify a value other than |
protocol | A list of the allowed protocol(s) for this flow. If you want this flow to be able to use any protocol within the internet protocol suite, use the value |
remote |
The remote IP address(es) to which UEs will connect for this flow. If you want to allow connections on any IP address, use the value |
template |
The name of the data flow template. This must be unique within the parent data flow policy rule. You must not use any of the following reserved strings - |
Property Details
direction
The direction of this flow.
direction: string
Property Value
string
ports
The port(s) to which UEs will connect for this flow. You can specify zero or more ports or port ranges. If you specify one or more ports or port ranges then you must specify a value other than ip
in the protocol
field. This is an optional setting. If you do not specify it then connections will be allowed on all ports. Port ranges must be specified as -. For example: [8080
, 8082-8085
].
ports?: string[]
Property Value
string[]
protocol
A list of the allowed protocol(s) for this flow. If you want this flow to be able to use any protocol within the internet protocol suite, use the value ip
. If you only want to allow a selection of protocols, you must use the corresponding IANA Assigned Internet Protocol Number for each protocol, as described in https://www.iana.org/assignments/protocol-numbers/protocol-numbers.xhtml. For example, for UDP, you must use 17. If you use the value ip
then you must leave the field port
unspecified.
protocol: string[]
Property Value
string[]
remoteIpList
The remote IP address(es) to which UEs will connect for this flow. If you want to allow connections on any IP address, use the value any
. Otherwise, you must provide each of the remote IP addresses to which the packet core instance will connect for this flow. You must provide each IP address in CIDR notation, including the netmask (for example, 192.0.2.54/24).
remoteIpList: string[]
Property Value
string[]
templateName
The name of the data flow template. This must be unique within the parent data flow policy rule. You must not use any of the following reserved strings - default
, requested
or service
.
templateName: string
Property Value
string