How to Set the PXE Service Point Response to PXE Requests
In Configuration Manager, you set the distribution point response to incoming PXE requests by setting the IsActive embedded property.
IsActive has the following possible values.
Value | Description |
---|---|
0 | The distribution point does not respond to PXE requests. |
1 | The distribution service point responds to requests. |
To set the distribution point response to PXE requests
Set up a connection to the SMS Provider. For more information, see SMS Provider fundamentals.
Make a connection to the distribution point instance with PXE enabled.
Get the embedded properties.
Update the IsActive embedded property.
Commit the changes to the site control file.
Example
The following example method sets the response for a PXE request based on the supplied String
value (allowResponse
).
For information about calling the sample code, see Calling Configuration Manager Code Snippets.
public void SetAllowResponse(WqlConnectionManager connection, string siteCode, string serverName, string allowResponse){ try { //Connect to distribution point instance. IResultObject siteRole = connection.GetInstance("SMS_SCI_SysResUse.FileType=2,ItemName=\"[\\\"Display=\\\\\\\\" + serverName + "\\\\\\\"]MSWNET:[\\\"SMS_SITE=" + siteCode + "\\\"]\\\\\\\\" + serverName + "\\\\,SMS Distribution Point\",ItemType=\"System Resource Usage\",SiteCode=" + "\"" + siteCode + "\""); // Create temporary copy of the embedded properties. Dictionary<string, IResultObject> embeddedProperties = siteRole.EmbeddedProperties; // Enumerate through the embedded properties and makes changes as needed. foreach (KeyValuePair<string, IResultObject> kvp in siteRole.EmbeddedProperties) { // Setting: IsActive if (kvp.Value.PropertyList["PropertyName"] == "IsActive") { // Get current property value. Console.WriteLine(); Console.WriteLine("Property: {0}", kvp.Value.PropertyList["PropertyName"]); Console.WriteLine("Current value: {0}", kvp.Value.PropertyList["Value"]); // Change value. embeddedProperties["IsActive"]["Value"].StringValue = allowResponse; Console.WriteLine("Setting the {0} value to {1}.", kvp.Value.PropertyList["PropertyName"], allowResponse); } } // Store the settings that have changed. siteRole.EmbeddedProperties = embeddedProperties; // Save the settings. siteRole.Put(); } catch (SmsException ex) { Console.WriteLine(); Console.WriteLine("Failed. Error: " + ex.InnerException.Message); }}
The example method has the following parameters:
Parameter | Type | Description |
---|---|---|
connection |
Managed: WqlConnectionManager |
A valid connection to the SMS Provider. |
siteCode |
Managed: String |
The Configuration Manager site code. |
serverName |
Managed: String |
The server name. For example, "SERVER1.DOMAIN1.COM" . |
allowResponse |
Managed: String |
The value to set whether the distribution point will respond to PXE requests. - 0 - The distribution point does not respond to PXE requests. - 1 - The PXE service point responds to requests from unknown computers. |
Compiling the Code
The C# example has the following compilation requirements:
Namespaces
System
System.Collections.Generic
System.Text
Microsoft.ConfigurationManagement.ManagementProvider
Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine
Assembly
microsoft.configurationmanagement.managementprovider
adminui.wqlqueryengine
Robust Programming
For more information about error handling, see About Configuration Manager Errors.
.NET Framework Security
For more information about securing Configuration Manager applications, see Configuration Manager role-based administration.
See Also
About OS deployment site role configuration
How to Read and Write to the Configuration Manager Site Control File by Using Managed Code
How to Read and Write to the Configuration Manager Site Control File by Using WMI