2.2.13.2.1 RopSynchronizationImportMessageChange ROP Request Buffer

The following descriptions define valid fields for the RopSynchronizationImportMessageChange ROP request buffer.


0


1


2


3


4


5


6


7


8


9

1
0


1


2


3


4


5


6


7


8


9

2
0


1


2


3


4


5


6


7


8


9

3
0


1

RopId

LogonId

InputHandleIndex

OutputHandleIndex

ImportFlag

PropertyValueCount

PropertyValues (variable)

...

RopId (1 byte):  An unsigned integer that specifies the type of ROP. For this operation this field is set to 0x72.

LogonId (1 byte):  An unsigned integer that specifies the logon associated with this operation.

InputHandleIndex (1 byte):  An unsigned integer index that specifies the location in the Server object handle table where the handle for the input Server object is stored. For more information about Server objects, see section 1.3.1.

OutputHandleIndex (1 byte):  An unsigned integer index that specifies the location in the Server object handle table where the handle for the output Server object will be stored.

ImportFlag (1 byte):  A flags structure that contains flags that control the behavior of the synchronization. The possible values are specified in [MS-OXCFXICS] section 2.2.3.2.4.2.1.

PropertyValueCount (2 bytes):  An unsigned integer that specifies the number of structures present in the PropertyValues field.

PropertyValues (variable):  An array of TaggedPropertyValue structures that specify extra properties on the message. The number of structures contained in this field is specified by the PropertyValueCount field. The format of the TaggedPropertyValue structure is specified in [MS-OXCDATA] section 2.11.4, and possible properties to be set are specified in [MS-OXCFXICS] section 2.2.3.2.4.2.1.