Set-SPProjectPCSSettings
Sets the settings for the Project Calculation Engine on Project Server.
Syntax
Set-SPProjectPCSSettings
[-ServiceApplication <PsiServiceApplicationPipeBind>]
[-AssignmentCollection <SPAssignmentCollection>]
[-CachePersistence <Int32>]
[-EditingSessionTimeout <Int32>]
[-MaximumIdleWorkersCount <Int32>]
[-MaximumProjectSize <Int32>]
[-MaximumSessionsPerUser <Int32>]
[-MaximumWorkersCount <Int32>]
[-MinimumMemoryRequired <Int32>]
[-RequestTimeLimits <Int32>]
[-NetTcpPort <Int32>]
[<CommonParameters>]
Description
The Set-SPProjectPCSSettings
cmdlet lets you configure the different settings that govern the operations of the Project Calculation Engine on Project Server.
The settings are per service application, which is identified by the Service Application parameter provided to this cmdlet.
The settings have maximum and minimum values that are enforced by Project Server.
For permissions and the most current information about Windows PowerShell for Project Server, see the online documentation at https://go.microsoft.com/fwlink/p/?LinkId=251833 (https://go.microsoft.com/fwlink/p/?LinkId=251833).
Examples
----------------------EXAMPLE-----------------------
Set-SPProjectPCSSettings -sa "Project Service Application" -MaximumSessionsPerUser 500
This example sets 500 as the maximum allowed Project Calculation Engine sessions that a user can open on the "Project Service Application" service application.
Parameters
-AssignmentCollection
Manages objects for the purpose of proper disposal. Use of objects, such as SPWeb or SPSite, can use large amounts of memory and use of these objects in Windows PowerShell scripts requires proper memory management. Using the SPAssignment object, you can assign objects to a variable and dispose of the objects after they are needed to free up memory. When SPWeb, SPSite, or SPSiteAdministration objects are used, the objects are automatically disposed of if an assignment collection or the Global parameter is not used.
When the Global parameter is used, all objects are contained in the global store.
If objects are not immediately used, or disposed of by using the Stop-SPAssignment
command, an out-of-memory scenario can occur.
Type: | SPAssignmentCollection |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-CachePersistence
The maximum length of time before the Project Calculation Engine can begin to remove temporary cache files of projects opened on the Project Server service application.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-EditingSessionTimeout
The maximum length of time that a user can be idle in a Project Calculation Engine session before a timeout occurs.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-MaximumIdleWorkersCount
The maximum number of idle Project Calculation Engine sessions available at a given time.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-MaximumProjectSize
The maximum size of a project that can be opened by the Project Calculation Engine.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-MaximumSessionsPerUser
The maximum number of sessions that a user is allowed to open.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-MaximumWorkersCount
The maximum number of Project Calculation Engine sessions that can be created.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-MinimumMemoryRequired
The minimum memory required before launching a new Project Calculation Engine session.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-NetTcpPort
The TCP port to use with the PCS service.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2016, Project Server 2019 |
-RequestTimeLimits
The maximum allowable time for a request to the Project Calculation Engine to complete before the Project Calculation Engine session is terminated.
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |
-ServiceApplication
The Project Server service application for which the settings are to be read.
Type: | PsiServiceApplicationPipeBind |
Aliases: | sa |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Applies to: | Project Server 2013, Project Server 2016, Project Server 2019 |