Disable-PhysicalDiskIdentification
Turns off the identification LED on the specified physical disk.
Syntax
Disable-PhysicalDiskIdentification
[-FriendlyName] <String>
[-CimSession <CimSession>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
Disable-PhysicalDiskIdentification
-UniqueId <String>
[-CimSession <CimSession>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
Disable-PhysicalDiskIdentification
-InputObject <CimInstance[]>
[-CimSession <CimSession>]
[-ThrottleLimit <Int32>]
[-AsJob]
[<CommonParameters>]
Description
The Disable-PhysicalDiskIndication cmdlet turns off the identification LED on the specified physical disk. The LED is typically used for visual identification of the location of a physical disk in an enclosure for removal and replacement operations. This cmdlet requires a storage enclosure that supports SCSI Enclosure Services (SES).
Examples
Example 1: Disable the identification LED on all physical disks in a pool
PS C:\> Get-PhysicalDisk -StoragePool $pool | Disable-PhysicalDiskIdentification
This example disables the identification LED on all physical disks associated with the storage pool in $pool.
Parameters
-AsJob
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
Type: | SwitchParameter |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-CimSession
Type: | CimSession |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-FriendlyName
Specifies the friendly name of the disk on which to turn off the identification LED.
Type: | String |
Position: | 0 |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-InputObject
Specifies the input object that is used in a pipeline command.
Type: | CimInstance[] |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
-ThrottleLimit
Type: | Int32 |
Position: | Named |
Default value: | None |
Required: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
-UniqueId
Specifies the UniqueID of the disk on which to turn off the identification LED.
Type: | String |
Aliases: | Id |
Position: | Named |
Default value: | None |
Required: | True |
Accept pipeline input: | True |
Accept wildcard characters: | False |
Notes
- When used in Failover Cluster, cmdlets from the Storage module operate on cluster level (all servers in the cluster).