CIM_DVDDrive class
Represents the capabilities and management of a DVDDrive.
Important The DMTF (Distributed Management Task Force) CIM (Common Information Model) classes are the parent classes upon which WMI classes are built. WMI currently supports only the CIM 2.x version schemas.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.
Syntax
class CIM_DVDDrive : CIM_MediaAccessDevice
{
uint16 Availability;
uint16 Capabilities[];
string CapabilityDescriptions[];
string Caption;
string CompressionMethod;
uint32 ConfigManagerErrorCode;
boolean ConfigManagerUserConfig;
string CreationClassName;
uint64 DefaultBlockSize;
string Description;
string DeviceID;
boolean ErrorCleared;
string ErrorDescription;
string ErrorMethodology;
uint16 FormatsSupported[];
datetime InstallDate;
uint32 LastErrorCode;
uint64 MaxBlockSize;
uint64 MaxMediaSize;
uint64 MinBlockSize;
string Name;
boolean NeedsCleaning;
uint32 NumberOfMediaSupported;
string PNPDeviceID;
uint16 PowerManagementCapabilities[];
boolean PowerManagementSupported;
string Status;
uint16 StatusInfo;
string SystemCreationClassName;
string SystemName;
};
Members
The CIM_DVDDrive class has these types of members:
- Properties
Properties
The CIM_DVDDrive class has these properties.
Availability
Data type: uint16
Access type: Read-only
Availability and status of the device. Inherited from CIM_LogicalDevice.
Value | Meaning |
---|---|
1 (0x1) | Other |
2 (0x2) | Unknown |
3 (0x3) | Running/Full Power |
4 (0x4) | Warning |
5 (0x5) | In Test |
6 (0x6) | Not Applicable |
7 (0x7) | Power Off |
8 (0x8) | Off Line |
9 (0x9) | Off Duty |
10 (0xA) | Degraded |
11 (0xB) | Not Installed |
12 (0xC) | Install Error |
13 (0xD) | Power Save - Unknown The device is known to be in a power save mode, but its exact status is unknown. |
14 (0xE) | Power Save - Low Power Mode The device is in a power save state but still functioning, and may exhibit degraded performance. |
15 (0xF) | Power Save - Standby The device is not functioning but could be brought to full power quickly. |
16 (0x10) | Power Cycle |
17 (0x11) | Power Save - Warning The device is in a warning state, though also in a power save mode. |
Capabilities
Data type: uint16 array
Access type: Read-only
Capabilities of the media access device.
Value | Meaning |
---|---|
0 | Unknown. |
1 | Other. |
2 | Sequential access. |
3 | Random access. |
4 | Writing. |
5 | Encryption. |
6 | Compression. |
7 | Removable media. |
8 | Manual cleaning. |
9 | Automatic cleaning. |
10 | SMART notification. |
11 | Dual-sided media. Distinguishes a device that can access both sides of dual-sided media from a device that reads only a single side and requires the media to be turned over. |
12 | Predismount eject not required. Indicates that the media does not have to be explicitly ejected from the device before being accessed by a picker element. |
CapabilityDescriptions
Data type: string array
Access type: Read-only
Array of free-form strings that provides detailed explanations for access device features indicated in the Capabilities array.
Note Each entry of this array is related to the entry in the Capabilities array, located at the same index.
Caption
Data type: string
Access type: Read-only
Short textual description of the object. This property is inherited from CIM_ManagedSystemElement.
CompressionMethod
Data type: string
Access type: Read-only
Free-form string that indicates the algorithm or tool used to compress the logical file. If the compression scheme is unknown or not described, use "Unknown". If the logical file is compressed, but the compression scheme is unknown or not described, use "Compressed". If the logical file is not compressed, use "Not Compressed".
ConfigManagerErrorCode
Data type: uint32
Access type: Read-only
Windows Configuration Manager error code.
Value | Meaning |
---|---|
0 (0x0) | Device is working properly. |
1 (0x1) | Device is not configured correctly. |
2 (0x2) | Windows cannot load the driver for this device. |
3 (0x3) | Driver for this device might be corrupted, or the system may be low on memory or other resources. |
4 (0x4) | Device is not working properly. One of its drivers or the registry might be corrupted. |
5 (0x5) | Driver for the device requires a resource that Windows cannot manage. |
6 (0x6) | Boot configuration for the device conflicts with other devices. |
7 (0x7) | Cannot filter. |
8 (0x8) | Driver loader for the device is missing. |
9 (0x9) | Device is not working properly; the controlling firmware is incorrectly reporting the resources for the device. |
10 (0xA) | Device cannot start. |
11 (0xB) | Device failed. |
12 (0xC) | Device cannot find enough free resources to use. |
13 (0xD) | Windows cannot verify the device's resources. |
14 (0xE) | Device cannot work properly until the computer is restarted. |
15 (0xF) | Device is not working properly due to a possible re-enumeration problem. |
16 (0x10) | Windows cannot identify all of the resources that the device uses. |
17 (0x11) | Device is requesting an unknown resource type. |
18 (0x12) | Device drivers must be reinstalled. |
19 (0x13) | Failure using the VxD loader. |
20 (0x14) | Registry might be corrupted. |
21 (0x15) | System failure. If changing the device driver is ineffective, see the hardware documentation. Windows is removing the device. |
22 (0x16) | Device is disabled. |
23 (0x17) | System failure. If changing the device driver is ineffective, see the hardware documentation. |
24 (0x18) | Device is not present, not working properly, or does not have all of its drivers installed. |
25 (0x19) | Windows is still setting up the device. |
26 (0x1A) | Windows is still setting up the device. |
27 (0x1B) | Device does not have valid log configuration. |
28 (0x1C) | Device drivers are not installed. |
29 (0x1D) | Device is disabled; the device firmware did not provide the required resources. |
30 (0x1E) | Device is using an IRQ resource that another device is using. |
31 (0x1F) | Device is not working properly; Windows cannot load the required device drivers. |
ConfigManagerUserConfig
Data type: boolean
Access type: Read-only
If TRUE, the device is using a user-defined configuration. This property is inherited from CIM_LogicalDevice.
CreationClassName
Data type: string
Access type: Read-only
Name of the class or subclass used in the creation of an instance. When used with other key properties of the class, this property allows all instances of the class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice.
DefaultBlockSize
Data type: uint64
Access type: Read-only
Default block size, in bytes, for the device.
For more information about using uint64 values in scripts, see Scripting in WMI.
Description
Data type: string
Access type: Read-only
Textual description of the object. This property is inherited from CIM_ManagedSystemElement.
DeviceID
Data type: string
Access type: Read-only
Address, or other identifying information to uniquely name the logical device. This property is inherited from CIM_LogicalDevice.
ErrorCleared
Data type: boolean
Access type: Read-only
If TRUE, the error reported in the LastErrorCode property is now cleared. This property is inherited from CIM_LogicalDevice.
ErrorDescription
Data type: string
Access type: Read-only
Free-form string that supplies information about the error recorded in the LastErrorCode property and corrective actions to perform. This property is inherited from CIM_LogicalDevice.
ErrorMethodology
Data type: string
Access type: Read-only
Free-form string that describes the types of error detection and correction supported by the device.
FormatsSupported
Data type: uint16 array
Access type: Read-only
The CD and DVD formats that are supported by this Device. For example, the drive may support "CD-ROM" and "DVD-RAM". In this case, the values 16 and 24 would be written to the array. This property's values align with those defined in the MediaType property of CIM_PhysicalMedia.
Unknown (0)
Other (1)
CD-ROM (16)
CD-ROM/XA (17)
CD-I (18)
CD Recordable (19)
DVD (22)
DVD-RW+ (23)
DVD-RAM (24)
DVD-ROM (25)
DVD-Video (26)
Divx (27)
CD-RW (33)
CD-DA (34)
CD+ (35)
DVD Recordable (36)
DVD-RW (37)
DVD-Audio (38)
DVD-5 (39)
DVD-9 (40)
DVD-10 (41)
DVD-18 (42)
InstallDate
Data type: datetime
Access type: Read-only
Date and time the object was installed. This property does not need a value to indicate that the object is installed. This property is inherited from CIM_ManagedSystemElement.
LastErrorCode
Data type: uint32
Access type: Read-only
Last error code reported by the logical device. This property is inherited from CIM_LogicalDevice.
MaxBlockSize
Data type: uint64
Access type: Read-only
Maximum block size, in bytes, for media accessed by the device.
For more information about using uint64 values in scripts, see Scripting in WMI.
MaxMediaSize
Data type: uint64
Access type: Read-only
Maximum size, in kilobytes, of media supported by this device. Kilobytes are interpreted as the number of bytes multiplied by 1000 (not the number of bytes multiplied by 1024).
For more information about using uint64 values in scripts, see Scripting in WMI.
MinBlockSize
Data type: uint64
Access type: Read-only
Minimum block size, in bytes, for media accessed by the device.
For more information about using uint64 values in scripts, see Scripting in WMI.
Name
Data type: string
Access type: Read-only
Label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement.
NeedsCleaning
Data type: boolean
Access type: Read-only
If TRUE, the media access device needs cleaning. Whether manual or automatic cleaning is possible is indicated in the Capabilities array property.
NumberOfMediaSupported
Data type: uint32
Access type: Read-only
Maximum number of multiple individual media that can be supported or inserted.
PNPDeviceID
Data type: string
Access type: Read-only
Windows Plug and Play device identifier of the logical device. This property is inherited from CIM_LogicalDevice.
Example: "*PNP030b"
PowerManagementCapabilities
Data type: uint16 array
Access type: Read-only
Array of the specific power-related capabilities of a logical device. This property is inherited from CIM_LogicalDevice.
Value | Meaning |
---|---|
0 (0x0) | Unknown |
1 (0x1) | Not Supported |
2 (0x2) | Disabled |
3 (0x3) | Enabled The power management features are currently enabled but the exact feature set is unknown or the information is unavailable. |
4 (0x4) | Power Saving Modes Entered Automatically The device can change its power state based on usage or other criteria. |
5 (0x5) | Power State Settable The SetPowerState method is supported. This method is found on the parent CIM_LogicalDevice class and can be implemented. For more information, see Designing Managed Object Format (MOF) Classes. |
6 (0x6) | Power Cycling Supported The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle). |
7 (0x7) | Timed Power On Supported The SetPowerState method can be invoked with the PowerState parameter set to 5 (Power Cycle) and Time set to a specific date and time, or interval, for power-on. |
PowerManagementSupported
Data type: boolean
Access type: Read-only
If TRUE, the device can be power managed, that is, put into a power-save state. If FALSE, the integer value 1 ("Not Supported") should be the only entry in the PowerManagementCapabilities array.
This property does not indicate whether power management features are currently enabled, or if enabled, which features are supported. For more information, see the PowerManagementCapabilities array. This property is inherited from CIM_LogicalDevice.
Status
Data type: string
Access type: Read-only
String that indicates the current status of the object. This property is inherited from CIM_ManagedSystemElement.
Values include the following:
"OK"
"Error"
"Degraded"
"Unknown"
"Pred Fail"
"Starting"
"Stopping"
"Service"
"Stressed"
"NonRecover"
"No Contact"
"Lost Comm"
StatusInfo
Data type: uint16
Access type: Read-only
State of the logical device. If this property does not apply to the logical device, the value 5 (Not Applicable) should be used. This property is inherited from CIM_LogicalDevice.
Value | Meaning |
---|---|
1 (0x1) | Other |
2 (0x2) | Unknown |
3 (0x3) | Enabled |
4 (0x4) | Disabled |
5 (0x5) | Not Applicable |
SystemCreationClassName
Data type: string
Access type: Read-only
Scoping system's creation class name. This property is inherited from CIM_LogicalDevice.
SystemName
Data type: string
Access type: Read-only
Scoping system's name. This property is inherited from CIM_LogicalDevice.
Requirements
Namespace |
Root\CIMV2 |