Share via


ICLRAssemblyIdentityManager::GetBindingIdentityFromStream Method

Gets the canonical assembly identity data for the assembly in the specified stream.

HRESULT GetBindingIdentityFromStream (
    [in] IStream    *pStream,
    [in] DWORD       dwFlags,
    [out, size_is(*pcchBufferSize)] LPWSTR pwzBuffer,
    [in, out] DWORD *pcchBufferSize
);

Parameters

  • pStream
    [in] The assembly stream to be evaluated.

  • dwFlags
    [in] Provided for future extensibility. CLR_ASSEMBLY_IDENTITY_FLAGS_DEFAULT is the only value that the current version of the common language runtime (CLR) supports.

  • pwzBuffer
    [out] A buffer containing the opaque assembly identity data.

  • pcchBufferSize
    [in, out] The size of pwzBuffer.

Return Value

HRESULT

Description

S_OK

The method returned successfully.

E_INVALIDARG

The supplied pStream is null.

ERROR_INSUFFICIENT_BUFFER

The size of pwzBuffer is too small.

HOST_E_CLRNOTAVAILABLE

The CLR has not been loaded into a process, or the CLR is in a state in which it cannot run managed code or process the call successfully.

HOST_E_TIMEOUT

The call timed out.

HOST_E_NOT_OWNER

The caller does not own the lock.

HOST_E_ABANDONED

An event was canceled while a blocked thread or fiber was waiting on it.

E_FAIL

An unknown catastrophic failure occurred. If a method returns E_FAIL, the CLR is no longer usable within the process. Subsequent calls to hosting methods return HOST_E_CLRNOTAVAILABLE.

Requirements

Platforms: Windows 2000, Windows XP, Windows Server 2003 family

Header: MSCorEE.idl

Library: Included as a resource in MSCorEE.dll

.NET Framework Version: 2.0

See Also

Concepts

ICLRAssemblyIdentityManager Interface

ICLRAssemblyReferenceList Interface