RemovePorts-com.vbs
By The Scripting Guys, Microsoft Corporation
This script deletes specified ports from Windows Firewall. To perform this task, it uses the Windows Firewall COM automation server. It runs only against the local computer. To close ports without removing stored port settings, use ClosePorts-com.vbs.
RemovePorts-com.vbs corresponds to ClosePort.vbs, one of the scripts that ships with Application Compatibility Testing and Mitigation Guide for Windows XP Service Pack 2 and which are documented in the Appendix. You can download a Windows Installer (.msi) file that installs the Guide and its associated scripts from:
To use the script, copy the code, paste it into Notepad, and then save the script as RemovePorts-com.vbs. To run the script, open a command prompt window to the directory of the script and type:
cscript removeports-com.vbs
If the default script host on the computer is Cscript.exe, the initial "cscript" may be omitted.
Script Code
'******************************************************************************
'RemovePorts-com.vbs
'Author: Peter Costantini, The Microsoft Scripting Guys
'Date: 8/26/04
'Version: 1.0
'This script deletes specified ports in the Windows Firewall.
'To close ports without removing stored port settings, use ClosePorts-com.vbs.
'******************************************************************************
Const NET_FW_IP_PROTOCOL_TCP = 6
Const NET_FW_IP_PROTOCOL_UDP = 17
'First dimension of arrRemovePorts must equal # of ports to be added minus 1.
Dim arrRemovePorts(2,1)
'Edit this list to remove ports from the exceptions list.
arrRemovePorts(0,0) = 137 'Port
arrRemovePorts(0,1) = NET_FW_IP_PROTOCOL_TCP 'Protocol
arrRemovePorts(1,0) = 138
arrRemovePorts(1,1) = NET_FW_IP_PROTOCOL_TCP
arrRemovePorts(2,0) = 552
arrRemovePorts(2,1) = NET_FW_IP_PROTOCOL_UDP
On Error Resume Next
'Create the firewall manager object.
Set objFwMgr = CreateObject("HNetCfg.FwMgr")
If Err <> 0 Then
WScript.Echo "Unable to connect to Windows Firewall."
WScript.Quit
End If
'Get the current profile for the local firewall policy.
Set objProfile = objFwMgr.LocalPolicy.CurrentProfile
Set colOpenPorts = objProfile.GloballyOpenPorts
WScript.Echo VbCrLf & "Ports removed:"
For i = 0 To UBound(arrRemovePorts)
intCount = 0
For Each objOpenPort In colOpenPorts
If (objOpenPort.Port = arrRemovePorts(i, 0)) And _
(objOpenPort.Protocol = arrRemovePorts(i, 1)) Then
intCount = 1
strName = objOpenPort.Name
intPort = objOpenPort.Port
intProtocol = objOpenPort.Protocol
intScope = objOpenPort.Scope
blnEnabled = objOpenPort.Enabled
colOpenPorts.Remove objOpenPort.Port, objOpenPort.Protocol
Exit For
End If
Next
If intCount = 1 Then
If Err = 0 Then
WScript.Echo VbCrLf & "Name: " & strName
WScript.Echo " Protocol: " & intProtocol
WScript.Echo " Port Number: " & intPort
WScript.Echo " Scope: " & intScope
WScript.Echo " Enabled: " & blnEnabled
Else
WScript.Echo VbCrLf & "Unable to remove port: " & intProtocol & _
" " & intNumber
End If
Err.Clear
Else
WScript.Echo VbCrLf & "Port " & arrRemovePorts(i, 1) & _
" " & arrRemovePorts(i, 0) & " not found."
End If
Next
Set colOpenPorts = objProfile.GloballyOpenPorts
WScript.Echo VbCrLf & "Open ports after operation:"
For Each objPort In colOpenPorts
WScript.Echo VbCrLf & "Name: " & objPort.Name
WScript.Echo " Protocol: " & objPort.Protocol
WScript.Echo " Port Number: " & objPort.Port
WScript.Echo " Scope: " & objPort.Scope
WScript.Echo " Remote Address: " & objPort.RemoteAddress
WScript.Echo " Enabled: " & objPort.Enabled
Next
For online peer support, join The Official Scripting Guys Forum! To provide feedback or report bugs in sample scripts, please start a new discussion on the Discussions tab for this script.
Disclaimer
This sample script is not supported under any Microsoft standard support program or service. The sample script is provided AS IS without warranty of any kind. Microsoft further disclaims all implied warranties including, without limitation, any implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample scripts and documentation remains with you. In no event shall Microsoft, its authors, or anyone else involved in the creation, production, or delivery of the scripts be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample scripts or documentation, even if Microsoft has been advised of the possibility of such damages.