CIM_iSCSISession class
iSCSISession is a network pipe between an initiator and target SCSIProtocolEndpoints. An iSCSISession is composed of one or more TCP connections which MUST be selected from a SystemSpecificCollection representing an iSCSI Portal Group. NetworkPipeComposition aggregates NetworkPipe instances representing iSCSI connections, which are associated to TCPProtocolEndpoints. Only an iSCSI initiator can create an iSCSI Session, an iSCSI Target MUST accept (or reject) a session request. EndOfNetworkPipe associates iSCSISession with SCSIProtocolEndpoint.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.
Syntax
[Abstract, Version("2.11.0"), UMLPackagePath("CIM::Network::Pipes")]
class CIM_iSCSISession : CIM_NetworkPipe
{
string Caption;
string Description;
string ElementName;
datetime InstallDate;
string Name;
uint16 OperationalStatus[];
string StatusDescriptions[];
string Status;
uint16 HealthState;
string OtherEnabledState;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
string InstanceID;
uint16 AggregationBehavior;
uint16 EnabledState = 5;
uint16 RequestedState = 512;
uint16 Directionality = 2;
uint16 SessionType;
uint32 TSIH;
string EndPointName;
uint32 CurrentConnections;
boolean InitialR2T;
boolean ImmediateData;
uint32 MaxOutstandingR2T;
uint32 MaxUnsolicitedFirstDataBurstLength;
uint32 MaxDataBurstLength;
boolean DataSequenceInOrder;
boolean DataPDUInOrder;
uint32 ErrorRecoveryLevel;
uint32 MaxConnectionsPerSession;
uint32 DefaultTimeToWait;
uint32 DefaultTimeToRetain;
};
Members
The CIM_iSCSISession class has these types of members:
Methods
The CIM_iSCSISession class has these methods.
Method | Description |
---|---|
RequestStateChange | Requests that the state of the element be changed to the value specified in the RequestedState parameter. When the requested state change takes place, the EnabledState and RequestedState of the element will be the same. Invoking the RequestStateChange method multiple times could result in earlier requests being overwritten or lost. If 0 is returned, then the task completed successfully and the use of ConcreteJob was not required. If 4096 (0x1000) is returned, then the task will take some time to complete, ConcreteJob will be created, and its reference returned in the output parameter Job. Any other return code indicates an error condition. This method is inherited from CIM_EnabledLogicalElement. |
Properties
The CIM_iSCSISession class has these properties.
-
AggregationBehavior
-
-
Data type: uint16
-
Access type: Read-only
Indicates whether the pipe is composed of lower-level pipes, and if so, how these lower-level pipes are aggregated (in parallel or in sequence). The specific instances of NetworkPipe that are combined are described using the NetworkPipeComposition association.
In the context of M.3100, the ability to be composed of lower-level pipes is modeled as a Trail. A Trail is made up of one or more Connections. (Note that both Trails and Connections are subclasses of Pipe). Because of the flexibility of the NetworkPipeComposition association, there is no need to subclass NetworkPipe, as was done in M.3100, but merely to instantiate the NetworkPipeComposition association to describe the bundling of the lower-level pipes (i.e., the connections), or the sequencing of them.
This property is inherited from CIM_NetworkPipe.
-
-
Unknown (0)
-
No Lower-Level Composition (2)
-
Combined In Parallel (3)
-
Combined In Sequence (4)
Caption
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (64)
The Caption property is a short textual description (one- line string) of the object.
This property is inherited from CIM_ManagedElement.
CurrentConnections
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: MinValue (1), MaxValue (65535), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnConnectionNumber"), ModelCorrespondence ("CIM_iSCSISessionSettings.MaxConnectionsPerSession")
The number of transport protocol connections that currently belong to this session.
DataPDUInOrder
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnDataPDUInOrder"), ModelCorrespondence ("CIM_iSCSISessionSettings.DataPDUInOrderPreference")
False indicates that iSCSI data PDUs within sequences MAY be in any order. True indicates that data PDUs within sequences MUST be at continuously increasing addresses, with no gaps or overlay between PDUs. Default is true.
DataSequenceInOrder
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnDataSequenceInOrder"), ModelCorrespondence ("CIM_iSCSISessionSettings.DataSequenceInOrderPreference")
False indicates that iSCSI data PDU sequences MAY be transferred in any order. True indicates that data PDU sequences MUST be transferred using continuously increasing offsets, except during error recovery.
DefaultTimeToRetain
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Seconds"), MinValue (0), MaxValue (3600), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiNodeDefaultTime2Retain"), ModelCorrespondence ("CIM_iSCSISessionSettings.DefaultTimeToRetainPreference")
The DefaultTime2Retain negotiated for this Session. This is the maximum time, in seconds after an initial wait (Time2Wait), before which an active iSCSI task reassignment is still possible after an unexpected connection termination or a connection reset.
DefaultTimeToWait
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Seconds"), MinValue (0), MaxValue (3600), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiNodeDefaultTime2Wait"), ModelCorrespondence ("CIM_iSCSISessionSettings.DefaultTimeToWaitPreference")
The DefaultTime2Wait negotiated for this Session. This is the minimum time, in seconds, to wait before attempting an explicit/implicit logout or active iSCSI task reassignment after an unexpected connection termination or a connection reset.
Description
-
Data type: string
-
Access type: Read-only
Contains a textual description of the object.
This property is inherited from CIM_ManagedElement.
Directionality
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: Override ("Directionality")
iSCSI sessions MUST be bidirectional.
ElementName
-
Data type: string
-
Access type: Read-only
Contains a user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.
This property is inherited from CIM_ManagedElement.
EnabledDefault
-
Data type: uint16
-
Access type: Read/write
An enumerated value indicating an administrator's default or startup configuration for the Enabled State of an element. By default, the element is "Enabled" (value=2).
This property is inherited from CIM_EnabledLogicalElement.
Enabled (2)
Disabled (3)
Not Applicable (5)
Enabled but Offline (6)
No Default (7)
Quiesce (9)
DMTF Reserved
Vendor Reserved
EnabledState
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: MappingStrings ("Recommendation.ITU|M3100.Pipe.operationalState")
An integer enumeration that indicates the enabled and disabled states of an element. It can also indicate the transitions between these requested states.
This property is inherited from CIM_NetworkPipe.
Unknown (0)
Other (1)
Enabled (2)
Disabled (3)
Shutting Down (4)
Not Applicable (5)
Enabled but Offline (6)
In Test (7)
Deferred (8)
Quiesce (9)
Starting (10)
DMTF Reserved
Vendor Reserved
EndPointName
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnInitiatorName", "MIB.IETF|iSCSI-MIB.iscsiSsnTargetName")
The iSCSI Port Name (iSCSIProtocolEndPoint.Name), of the device at the other end of this iSCSISession.
ErrorRecoveryLevel
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: MinValue (1), MaxValue (255), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnErrorRecoveryLevel"), ModelCorrespondence ("CIM_iSCSISessionSettings.ErrorRecoveryLevelPreference")
The level of error recovery negotiated between the initiator and the target. Higher numbers represent more detailed recovery schemes.
HealthState
-
Data type: uint16
-
Access type: Read-only
Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its sub-components.
This property is inherited from CIM_ManagedSystemElement.
The following values have been defined:
Unknown (0)
The implementation cannot report on HealthState at this time.
OK (5)
The element is fully functional and is operating within normal operational parameters and without error.
Degraded/Warning (10)
The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors
Minor failure (15)
All functionality is available but some might be degraded.
Major failure (20)
The element is failing. It is possible that some or all of the functionality of this component is degraded or not working.
Critical failure (25)
The element is non-functional and recovery might not be possible.
Non-recoverable error (30)
The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost.
DMTF Reserved
DMTF has reserved the unused portion of the continuum for additional HealthStates in the future.
ImmediateData
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnImmediateData"), ModelCorrespondence ("CIM_iSCSISessionSettings.ImmediateDataPreference")
Indicates whether the initiator and target have agreed to support immediate data on this session.
InitialR2T
-
Data type: boolean
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnInitialR2T"), ModelCorrespondence ("CIM_iSCSISessionSettings.InitialR2TPreference")
If set to true, indicates that the initiator MUST wait for an R2T before sending to the target. If set to false, the initiator MAY send data immediately, within limits set by iscsiSsnFirstBurstLength and the expected data transfer length of the request.
InstallDate
-
Data type: datetime
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5")
Indicates when the object was installed. The lack of a value does not indicate that the object is not installed.
This property is inherited from CIM_ManagedSystemElement.
InstanceID
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key, MappingStrings ("Recommendation.ITU|M3100.TrailR1.trailId", "Recommendation.ITU|M3100.ConnectionR1.connectionID", "Recommendation.ITU|M3100.SubNetworkConnection.subNetworkConnectionID")
Within the scope of the instantiating Namespace, InstanceID opaquely and uniquely identifies an instance of this class. In order to ensure uniqueness within the NameSpace, the value of InstanceID SHOULD be constructed using the following 'preferred' algorithm:
<OrgID>:<LocalID>
Where <OrgID> and <LocalID> are separated by a colon ':', and where <OrgID> MUST include a copyrighted, trademarked or otherwise unique name that is owned by the business entity creating/defining the InstanceID, or is a registered ID that is assigned to the business entity by a recognized global authority. (This is similar to the <Schema Name>_<Class Name> structure of Schema class names.) In addition, to ensure uniqueness <OrgID> MUST NOT contain a colon (':'). When using this algorithm, the first colon to appear in InstanceID MUST appear between <OrgID> and <LocalID>. (For DMTF defined instances, the 'preferred' algorithm MUST be used with the <OrgID> set to 'CIM'.)
<LocalID> MUST include either a vendor specified unique identifier, or if mapping from an ITU M.3100 environment, the trailID, connectionID or subNetworkConnectionID of the instances of PipeR2.
This property is inherited from CIM_NetworkPipe.
MaxConnectionsPerSession
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: MinValue (1), MaxValue (65535), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiNodeMaxConnections"), ModelCorrespondence ("CIM_iSCSISessionSettings.MaxConnectionsPerSession")
The maximum number of connections allowed in this session.
MaxDataBurstLength
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Bytes"), MinValue (512), MaxValue (16777215), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnMaxBurstLength"), ModelCorrespondence ("CIM_iSCSISessionSettings.MaxDataBurstLength")
The maximum number of bytes which can be sent within a single sequence of Data-In or Data-Out PDUs.
MaxOutstandingR2T
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Bytes"), MinValue (1), MaxValue (65535), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnMaxOutstandingR2T"), ModelCorrespondence ("CIM_iSCSISessionSettings.MaxOutstandingR2T")
The maximum number of outstanding request-to-transmit (R2T)s per iSCSI task within this session.
MaxUnsolicitedFirstDataBurstLength
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: Units ("Bytes"), MinValue (512), MaxValue (16777215), MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnFirstBurstLength"), ModelCorrespondence ("CIM_iSCSISessionSettings.MaxUnsolicitedFirstDataBurstLength")
The maximum length supported for unsolicited data sent within this session.
Name
-
Data type: string
-
Access type: Read-only
-
Qualifiers: MaxLen (1024)
The Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property.
This property is inherited from CIM_ManagedSystemElement.
OperationalStatus
-
Data type: uint16 array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")
Contains indicators of the current status of the element. The first value of OperationalStatus should contain the primary status for the element.
Note
OperationalStatus replaces the deprecated Status property. Due to the widespread use of the existing Status property in management applications, Microsoft strongly recommends that providers or instrumentation provide both the Status and OperationalStatus properties. When instrumented, Status (because it is single-valued) should also provide the primary status of the element.
This property is inherited from CIM_ManagedSystemElement.
The following values have been defined:
Unknown (0)
Indicates the implementation cannot report on OperationalStatus at this time.
Other (1)
Indicates an undefined state.
OK (2)
Indicates full functionality without errors.
Degraded (3)
Indicates the element is working and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors
Stressed (4)
Indicates that the element is functioning, but needs attention. Overload and overheated are examples of Stressed states.
Predictive Failure (5)
Indicates that an element is functioning nominally but predicting a failure in the near future.
Error (6)
Indicates that an error has occurred.
Non-Recoverable Error (7)
A non-recoverable error has occurred.
Starting (8)
The job is starting.
Stopping (9)
The job is stopping.
Stopped (10)
The element has been intentionally stopped.
In Service (11)
Indicates the element is being configured, maintained, cleaned, or otherwise administered.
No Contact (12)
Indicates that the monitoring system has knowledge of this element, but has never been able to establish communications with it.
Lost Communication (13)
Indicates that the job is known to exist and has been contacted successfully in the past, but is currently unreachable.
Aborted (14)
Indicates the job stopped in an unexpected way. The state and configuration of the job might need to be updated.
Dormant (15)
Indicates that the job is inactive.
Supporting Entity in Error (16)
Indicates that an element on which this job depends is in error. This element may be OK but is unable to function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems.
Completed (17)
Indicates that the job has completed its operation. This value should be combined with either OK, ErrorError, or Degraded so that a client can tell if the complete operation Completed with OK (passed), Completed with Error (failed), or Completed with Degraded (the operation finished, but it did not complete OK or did not report an error).
Power Mode (18)
"Power Mode" indicates that the element has additional power model information contained in the associated PowerManagementService association.
DMTF Reserved
DMTF has reserved this portion of the range for additional OperationalStatus values in the future.
Vendor Reserved
Microsoft has reserved the unused portion of the range for additional OperationalStatus values in the future.
OtherEnabledState
-
Data type: string
-
Access type: Read-only
-
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 ("Other"). This property must be set to null when EnabledState is any value other than 1.
This property is inherited from CIM_EnabledLogicalElement.
RequestedState
-
Data type: uint16
-
Access type: Read/write
-
Qualifiers: MappingStrings ("Recommendation.ITU|M3100.Pipe.administrativeState")
Indicates the last requested or desired state for the element. The actual state of the element is represented by EnabledState.
This property is inherited from CIM_NetworkPipe.
Enabled (2)
Disabled (3)
Shut Down (4)
No Change (5)
Offline (6)
Test (7)
Deferred (8)
Quiesce (9)
Reboot (10)
Reset (11)
Not Applicable (12)
DMTF Reserved
Vendor Reserved
SessionType
-
Data type: uint16
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnType")
iSCSI Session type.
Discovery (2)
Normal (3)
Status
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)
Contains a string indicating the primary status of the object.
Note
This property is deprecated and replaced by the OperationalStatus property. If you choose to use the Status property for backward compatibility it should be secondary to the OperationalStatus property.
This property is inherited from CIM_ManagedSystemElement.
("OK")
("Error")
("Degraded")
("Unknown")
("Pred Fail")
("Starting")
("Stopping")
("Service")
("Stressed")
("NonRecover")
("No Contact")
("Lost Comm")
("Stopped")
StatusDescriptions
-
Data type: string array
-
Access type: Read-only
-
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")
Contains strings describing the corresponding values in the OperationalStatus array. For example, if an element in OperationalStatus contains the value Stopping, then the element at the same array index in this property may contain an explanation as to why an object is being stopped.
This property is inherited from CIM_ManagedSystemElement.
TimeOfLastStateChange
-
Data type: datetime
-
Access type: Read-only
The date or time when the EnabledState of the element last changed. If the state of the element has not changed and this property is populated, then it must be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property must not be updated.
This property is inherited from CIM_EnabledLogicalElement.
TSIH
-
Data type: uint32
-
Access type: Read-only
-
Qualifiers: MappingStrings ("MIB.IETF|iSCSI-MIB.iscsiSsnTSIH")
The Target Session Identifying Handle (TSIH) for this session.
Requirements
Minimum supported client |
None supported |
Minimum supported server |
Windows Server 2012 R2 |
Namespace |
Root\CIMv2\Storage\iScsiTarget |
MOF |
|
DLL |
|