Configuration File Parameters for the Radiometrics Test (Windows Embedded CE 6.0)
1/6/2010
The following table shows the mandatory parameters for the Stinger.ini file.
Parameter | Description |
---|---|
DS_VOICE_NUMBER0 |
IVR server telephone number |
DS_VOICE_NUMBER1 |
Conference number of IVR server (same as DS_VOICE_NUMBER0) |
DS_VOICE_NUMBER2 |
Second conference number (second line) |
DS_NUMBER_BUSY |
Always busy telephone number |
RILT_SIM_PWD |
SIM PIN value |
SIM_VOICE_NUMBER |
Telephone number for your device |
RILT_GPRS_APN |
Access point name of GPRS/Edge connection |
The following table shows the optional parameters for the Stinger.ini file.
Parameter | Description |
---|---|
DS_DELAY |
The period between the MO call and MT callback |
DS_SLEEP |
The period between call tests |
SIM_CALL_FORWARD_NUMBER |
The number used during the call forwarding test |
DS_BUSY_SLEEP |
The delay between calling the busy number |
NW_DELAY |
The delay between supplementary services |
RILT_CMTI |
Set this if the network supports +CMTI instead of +CMT |
GPRS_USER_NAME |
The GPRS user name (if required by the network) |
GPRS_PASSWORD |
The GPRS password (if required by the network) |
GPRS_DOMAIN |
The GPRS domain (if required by the network) |
CSD_NUMBER |
The CSD dialup phone number |
CSD_USER_NAME |
The CSD dialup account user name |
CSD_PASSWORD |
The CSD dialup account password |
CSD_DOMAIN |
The CSD dialup account domain |
The specified test configuration file (if no filename is specified, Ltk.ini is used) contains parameter information specific to the test suites you are running. The following table shows the mandatory parameters for the test configuration file.
Parameter | Description |
---|---|
BLOCKS_PER_SESSION |
Data blocks to transfer during a connect or disconnect |
BLOCK_SIZE |
Size, in bytes, of each data block |
DOWNLOAD_URL |
URL to use for data transfer |
The following table shows the optional parameters for the test configuration file.
Parameter | Description |
---|---|
METRIC_NAME |
Gathers and displays test results as a metric. The following list shows the supported values:
|
DURATION |
Specifies the duration of the test, in hours. The default value is 0, meaning that the test will finish when all test cases have been executed. |
CONSECUTIVE_FAILS_ALLOWED |
Specifies the number of test cases that are allowed to fail before the test aborts. |
TOTAL_GPRS_SIZE |
Specifies the total number of bytes to be downloaded during the entire test. |
The test configuration file also defines the test order along with the number of times each test should be run. The BeginTestSequence string is required at the beginning of the test sequence information. The EndTestSequence string is required at the end of the test sequence information. The following example shows the test sequence information from a sample test configuration file.
BeginTestSequence
You can also instruct the test suite to run a random test by using the random command, which forces the test suite to select and run a test randomly.
Note
It is strongly recommended that you employ random testing to expose functional defects that might not otherwise be exposed.