Per-Line Settings
The per-line settings specify which lines the RAS server will use to listen for incoming connections from clients, and to specify settings on an individual line basis.
The per-line registry settings are located under the HKEY_LOCAL_MACHINE\Comm\ppp\Server\Line\<DeviceName>\ registry key.
You can discover available device names by using the RasEnumDevices function.
The following table shows the named values for the HKEY_LOCAL_MACHINE\Comm\ppp\Server\Line\<DeviceName>\ registry key.
Value : type | Description |
---|---|
Enable : REG_DWORD | Default setting is 0. Specifies whether incoming connections are enabled on the line. Setting this value 1 will enable incoming connections on the line./ |
DeviceType : REG_SZ | Specifies the type of device. This setting is one of the following RASDT_xxx values from sdk\inc\ras.h:
|
DeviceInfo : REG_BINARY | Specifies device configuration information, which is opaque to the RAS server. This information is used to configure the device when it is being initialized to listen for incoming connections. |
Flags : REG_DWORD | Default setting is 0. This value specifies a set of per-line configuration options. It is a bitmask of the following option values:
This value is identical to the Global Server Flags value. The flags in use for a particular line are determined by ORing together the global flags with the per-line flags. |