Test.Confidence

The test verifies that the device can report lack of confidence when a contact exceeds the size of an intentional finger contact.

Test details

Associated requirements

Device.Input.PrecisionTouchpad.HIDCompliance.HIDCompliance

See the device hardware requirements.

Platforms

Windows RT 8.1 Windows 8.1 x64 Windows 8.1 x86

Expected run time

~2 minutes

Categories

Certification

Type

Manual

 

Running the test

Before you run the test, complete the test setup as described in the test requirements: Mouse or other Pointing Device Testing Prerequisites.

  1. Start the test.

  2. Put a 27mm-29mm diameter contact straight down onto the surface of the touchpad for at least five seconds.

  3. Remove the contact. PTLogo will automatically verify that the confidence bit was cleared in the required time and remained cleared for the contact lifetime. If no reporting errors are detected, the test will automatically pass the iteration.

Troubleshooting

For troubleshooting information, see Troubleshooting Device.Input Testing.

Error Description/Workaround

[30] confidence bit set too long

The device dos not clear the confidence bit within 50ms of contact reporting.

[[7] test didn’t receive enough data

Lifted off of the touchpad too early.

Retry the test. Make sure to keep the contact on the touchpad surface for at least five seconds.

 

More information

Command syntax

Command Description

ptlogo.exe Test.Confidence.json

Runs the test.

 

File list

File Location

ptlogo.exe

<testbinroot>\input\PrecisionTouchpad\

config.json

<testbinroot>\input\PrecisionTouchpad\

Test.Confidence.json

<testbinroot>\input\PrecisionTouchpad\

 

 

 

Send comments about this topic to Microsoft