Test.Geometry
The test verifies that if the device supports sending contact geometry, the device can accurately report contact geometry within required tolerances.
Test details
Associated requirements |
Device.Input.PrecisionTouchpad.Precision.Geometry |
Platforms |
Windows RT 8.1 Windows 8.1 x64 Windows 8.1 x86 |
Expected run time |
~2 minutes |
Categories |
Certification |
Type |
Manual |
Running the test
Before you run the test, complete the test setup as described in the test requirements: Mouse or other Pointing Device Testing Prerequisites.
In addition, this test requires the following additional hardware:
Quantity 2: 7mm diameter capacitive contacts
Quantity 2: 9mm diameter capacitive contacts
Quantity 2: 11mm diameter capacitive contacts
Quantity 2: 7mmx11mm elliptical capacitive contacts
Quantity 2: 9mmx14mm elliptical capacitive contacts
Quantity 2: 11mmx16mm elliptical capacitive contacts
Precision contacts are required for this test. You must use a precise mechanism such as a PT3, other precision rig, or robot to place the contacts.
Start the test.
If the device does not support geometry, tap to automatically pass all 24 iterations.
If the device supports geometry, perform the following steps:
For iterations one and two, place one 7mm diameter contact anywhere on the touchpad for five seconds.
For iterations three and four, place one 9mm diameter contact anywhere on the touchpad for five seconds.
For iterations five and six, place one 11mm diameter contact anywhere on the touchpad for five seconds.
For iterations seven and eight, place one 7mmx11mm elliptical contact with the major axis vertically aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations nine and ten, place one 7mmx11mm elliptical contact with the major axis horizontally aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 11 and 12, place one 9mmx14mm elliptical contact with the major axis vertically aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 13 and 14, place one 9mmx14mm elliptical contact with the major axis horizontally aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 15 and 16, place one 11mmx16mm elliptical contact with the major axis vertically aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 17 and 18, place one 11mmx16mm elliptical contact with the major axis horizontally aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 19 and 20, place two 7mmx11mm elliptical contact with the major axis of both contacts vertically aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 21 and 22, place two 9mmx14mm elliptical contact with the major axis of both contacts vertically aligned to the touchpad anywhere on the touchpad for five seconds.
For iterations 23 and 24, place two 11mmx16mm elliptical contact with the major axis of both contacts vertically aligned to the touchpad anywhere on the touchpad for five seconds.
Troubleshooting
For troubleshooting information, see Troubleshooting Device.Input Testing.