Share via


SCSI Compliance Fuzz Test (LOGO)

This automated verifies that Fibre Channel or Fibre Channel over Ethernet controllers work properly after a fuzz test.

Test details

Associated requirements

Device.Storage.Controller.Fc.Interface Device.Storage.Controller.Fcoe.Interface Device.Storage.Controller.Fcoe.Interoperability

See the device hardware requirements.

Platforms

Windows Server 2012 (x64) Windows Server 2012 R2

Expected run time

~300 minutes

Categories

Certification Reliability

Type

Automated

 

Running the test

Before you run the test, complete the test setup as described in the test requirements: Fibre Channel Adapter Testing Prerequisites or Fibre Channel Over Ethernet Testing Prerequisites.

Troubleshooting

For troubleshooting information, see Troubleshooting Device.Storage Testing.

Before you run this test, if the test environment is an HBA Boot environment, make sure at least one non-boot LUN is connected to the HBA.

More information

The test sends the fuzzed commands to the device. The commands covered by test are the same as the SCSI Compliance Test 2.0 (LOGO).

Parameters

Parameter Description

DiskDeviceObjLink

The device object link.

 

Command syntax

Command Description

fuzztest.exe /device "[DiskDeviceObjLink]" /scenario fuzz /operation test /seed 123456 /feature common

Runs the test.

 

Note  

For command-line help for this test binary, type /h.

 

File list

File Location

Fuzztest.exe

<[testbinroot]>\nttest\DRIVERSTEST\storage\wdk\

strgenrt.dll

<[osbinroot]>\SecuTest\SecuTest\

SecuScript.dll

<[osbinroot]>\SecuTest\SecuTest\

FieldObjects.dll

<[osbinroot]>\SecuTest\SecuTest\

CoreLib.dll

<[osbinroot]>\SecuTest\SecuTest\

 

 

 

Send comments about this topic to Microsoft