WGF11 Fill Rules
This automated test verifies whether the device is consistent with the triangle fill rules and point fill rules as detailed in the DX11 specification.
The test draws geometry in various orientations relative to sample locations, and verifies that fill rules are observed. Test cases cycle on different formats, pixel positions, sample counts, quality levels, and sample indices. The geometry drawn can be a triangle or a point.
This topic applies to the following test jobs:
WGF11 Fill Rules
WGF11 Fill Rules (WoW64)
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 10 |
Category | Compatibility |
Timeout (in minutes) | 600 |
Requires reboot | false |
Requires special configuration | false |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Running the test
Before you run the test, complete the test setup as described in the test requirements: Graphic Adapter or Chipset Testing Prerequisites..
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.
For troubleshooting information, see Troubleshooting Device.Graphics Testing.
Test cases return one of the following results:
Pass
Fail
Blocked
Skipped
The log file contains specific details about the test cases that are failed, blocked, or skipped. A test case will return Skipped if it is invalid according to the hardware configuration (some features are optional and may not be supported by some hardware) and the command line options (some test cases are only valid for certain feature levels). A test case will return Blocked if the failure is caused by reasons other than the tested feature. To review test details, review the test log from the Windows HLK Manager.
More information
.
Command syntax
Command option | Description |
---|---|
Wgf11fillrules |
Runs the test jobs. Without any options, the test enumerates devices. |
-FeatureLevel:XX.X |
Sets the feature level, where XX.X is the Feature Level the test will run at: 10.0, 10.1, or 11.0. |
Note
For command line help for this test binary, type /?.
File list
File | Location |
---|---|
Configdisplay.exe |
<[testbinroot]>\nttest\windowstest\tools\ |
D3d11_1sdklayers.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support\ |
D3d11ref.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support\ |
D3d11sdklayers.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support\ |
D3dcompiler_test.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support |
D3dx10_test.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support\ |
d3dx11_test.dll |
<[testbinroot]>\nttest\windowstest\graphics\d3d\support\ |
TDRWatch.exe |
<[testbinroot]>\nttest\windowstest\graphics\ |
Wgf11fillrules.exe |
<[testbinroot]>\nttest\windowstest\graphics\d3d\conf |
Parameters
Parameter name | Parameter description |
---|---|
MODIFIEDCMDLINE | Additional command line arguments for test executable |
LLU_NetAccessOnly | LLU Name of net user |
ConfigDisplayCommandLine | Custom Command Line for ConfigDisplay. Default: logo |
TDRArgs | /get or /set |