WDDM HPD Notification Test (Manual)
This manual test verifies support for notification events about Hot Plug Detect (HPD) removal and arrival.
This test is a user-mode test. You first generate an HPD removal event by unplugging a computer monitor. Then, plug in the monitor. The test reports success if it detects the arrival event after it detects the removal event.
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 5 |
Category | Compatibility |
Timeout (in minutes) | 300 |
Requires reboot | false |
Requires special configuration | false |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Running the test
Before you run the test, complete the test setup as described in the test requirements: Graphic Adapter or Chipset Testing Prerequisites.
Warning
Make sure that the computer can run all manual tests that are required for certification. Depending on the type of submission, prerequisites may include the following:
TV Out support
Multimonitor support
Hot plug detection support
When you are running this test, select one computer in your pool, set the necessary dimension, and then schedule all jobs that have "(Manual)" in the title at the same time. You can do this before or after the rest of the automated jobs so that they are sent to the system in bulk.
You can set the dimension for this test by using either of the following methods:
Type this command at a command prompt:
WTTCmd.exe /ConfigReg /Add /Value:Display\PrimaryMachine /Data:""
Use this procedure:
Pick a relevant computer in the pool via job monitor.
Right-click the computer name in the pool, and then click Edit.
Add the dimension to the list.
Click Save.
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.
For troubleshooting information, see Troubleshooting Device.Graphics Testing.
More information
Command syntax
Command option | Description |
---|---|
HPDNotification |
Runs the WDDM HPD Notification Test (Manual) test job. |
Note
For command-line help for this test binary, type /h.
File list
File | Location |
---|---|
Configdisplay.exe |
<[testbinroot]>\nttest\windowstest\tools\ |
HPDNotification.exe |
<[testbinroot]>\nttestnttest\windowstest\graphics\wddm\bin\ |
TDRWatch.exe |
<[testbinroot]>\nttest nttest\windowstest\graphics\ |
Parameters
Parameter name | Parameter description |
---|---|
LLU_NetAccessOnly | LLU Name of net user |
ConfigDisplayCommandLine | Custom Command Line for ConfigDisplay. Default: logo |
TDRArgs | /get or /set |