How to Configure Remote Tools Settings
Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2
In Microsoft System Center Configuration Manager 2007, you set the Remote Tools Client Agent settings by modifying the necessary site control file settings.
To configure Remote Tools settings
Set up a connection to the SMS Provider.
Make a connection to the Remote Tools Client Agent section of the site control file by using the SMS_SCI_ClientComp class.
Loop through the array of available properties, making changes as needed.
Commit the changes to the site control file.
Example
The following example sets the Remote Tools Client Agent settings by using the SMS_SCI_ClientComp class to connect to the site control file and change properties.
For information about calling the sample code, see Calling Configuration Manager Code Snippets.
Sub ConfigureRemoteControlClientAgentSettings(swbemServices, _
swbemContext, _
siteCode, _
enableDisableClientAgent, _
newPermissionRequired, _
newVisibleSignal, _
newAudibleSignal)
' Load the site control file and get the remote tools client agent section.
swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteCode & """", "Refresh", , , swbemContext
Query = "SELECT * FROM SMS_SCI_ClientComp " & _
"WHERE ClientComponentName = 'Remote Control' " & _
"AND SiteCode = '" & siteCode & "'"
Set SCIComponentSet = swbemServices.ExecQuery(Query, ,wbemFlagForwardOnly Or wbemFlagReturnImmediately, swbemContext)
' Only one instance is returned from the query.
For Each SCIComponent In SCIComponentSet
' Set the client agent by setting the Flags value to 0 or 1 using the enableDisableClientAgent variable.
wscript.echo " "
wscript.echo "Remote Control Agent"
wscript.echo "Current value " & SCIComponent.Flags
' Modify the value.
SCIComponent.Flags = enableDisableClientAgent
wscript.echo "New value " & enableDisableClientAgent
' Loop through the array of embedded SMS_EmbeddedProperty instances.
For Each vProperty In SCIComponent.Props
' Setting: Permission Required
If vProperty.PropertyName = "Permission Required" Then
wscript.echo " "
wscript.echo vProperty.PropertyName
wscript.echo "Current value " & vProperty.Value
'Modify the value.
vProperty.Value = newPermissionRequired
wscript.echo "New value " & newPermissionRequired
End If
' Setting: Visible Signal
If vProperty.PropertyName = "Visible Signal" Then
wscript.echo " "
wscript.echo vProperty.PropertyName
wscript.echo "Current value " & vProperty.Value
' Modify the value.
vProperty.Value = newVisibleSignal
wscript.echo "New value " & newVisibleSignal
End If
' Setting: Audible Signal
If vProperty.PropertyName = "Audible Signal" Then
wscript.echo " "
wscript.echo vProperty.PropertyName
wscript.echo "Current value " & vProperty.Value
' Modify the value.
vProperty.Value = newAudibleSignal
wscript.echo "New value " & newAudibleSignal
End If
Next
' Update the component in your copy of the site control file. Get the path
' to the updated object, which could be used later to retrieve the instance.
Set SCICompPath = SCIComponent.Put_(wbemChangeFlagUpdateOnly, swbemContext)
Next
'Commit the change to the actual site control file.
Set InParams = swbemServices.Get("SMS_SiteControlFile").Methods_("CommitSCF").InParameters.SpawnInstance_
InParams.SiteCode = siteCode
swbemServices.ExecMethod "SMS_SiteControlFile", "CommitSCF", InParams, , swbemContext
' Release the copy of the site control file.
swbemServices.Get("SMS_SiteControlFile").ReleaseSessionHandle swbemContext.Item("SessionHandle").Value
End Sub
public void ConfigureRemoteControlClientAgentSettings(WqlConnectionManager connection,
string siteCode,
string enableDisableRemoteControlClientAgent,
string newPermissionRequired,
string newVisibleSignal,
string newAudibleSignal)
{
try
{
IResultObject siteDefinition = connection.GetInstance(@"SMS_SCI_ClientComp.FileType=1,ItemType='Client Component',SiteCode='" + siteCode + "',ItemName='Remote Control'");
// Setting: Enable Remote Control Client Agent
// Set Remote Control client agent by setting flags value to 0 or 1 using the EnableDisableRemoteControlClientAgent variable.
Console.WriteLine();
Console.WriteLine("Remote Control Client Agent");
Console.WriteLine("Current value: " + siteDefinition["Flags"].StringValue);
// Change value using the enableDisableRemoteControlClientAgent value passed in.
siteDefinition["Flags"].StringValue = enableDisableRemoteControlClientAgent;
Console.WriteLine("New value : " + enableDisableRemoteControlClientAgent);
foreach (KeyValuePair<string, IResultObject> kvp in siteDefinition.EmbeddedProperties)
{
// Create temporary working copy of embedded properties.
Dictionary<string, IResultObject> embeddedProperties = siteDefinition.EmbeddedProperties;
// Setting: Permission Required.
if (kvp.Value.PropertyList["PropertyName"] == "Permission Required")
{
Console.WriteLine();
Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue);
// Change value using the newPermissionRequired value passed in.
embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue = newPermissionRequired;
Console.WriteLine("New value : " + newPermissionRequired);
}
// Setting: Visible Signal.
if (kvp.Value.PropertyList["PropertyName"] == "Visible Signal")
{
Console.WriteLine();
Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue);
// Change value using the newScanSchedule value passed in.
embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue = newVisibleSignal;
Console.WriteLine("New value : " + newVisibleSignal);
}
// Setting: Audible Signal.
if (kvp.Value.PropertyList["PropertyName"] == "Audible Signal")
{
Console.WriteLine();
Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue);
// Change value using the newAudibleSignal value passed in.
embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue = newAudibleSignal;
Console.WriteLine("New value : " + newAudibleSignal);
}
// Store the settings that have changed.
siteDefinition.EmbeddedProperties = embeddedProperties;
}
// Save the settings.
siteDefinition.Put();
}
catch (SmsException ex)
{
Console.WriteLine("Failed. Error: " + ex.InnerException.Message);
throw;
}
}
The example method has the following parameters:
Parameter |
Type |
Description |
connection |
|
A valid connection to the SMS Provider. |
siteCode |
|
The site code. |
enableDisableClientAgent |
|
Determines whether the Remote Tools Client Agent is enabled or disabled. 0 - disabled 1 - enabled |
newPermissionRequired |
|
Determines whether permission is required to remote control. 0 - not required 1 - required |
newVisibleSignal |
|
Determines whether the visible signal is enabled or disabled. 0 - disabled 1 - enabled |
newAudibleSignal |
|
Determines whether the audible signal is enabled or disabled. 0 - disabled 1 - enabled |
Compiling the Code
This C# example requires:
Namespaces
System
System.Collections.Generic
System.Text
Microsoft.ConfigurationManagement.ManagementProvider
Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine
Assembly
adminui.wqlqueryengine
microsoft.configurationmanagement.managementprovider
Robust Programming
For more information about error handling, see About Configuration Manager Errors.
Security
For more information about securing Configuration Manager applications, see Securing Configuration Manager Applications.
See Also
Concepts
System Center Configuration Manager Software Development Kit
About Configuration Manager Remote Tools
About the Configuration Manager Site Control File
How to Read and Write to the Configuration Manager Site Control File by Using Managed Code
How to Read and Write to the Configuration Manager Site Control File by Using WMI
SMS_SCI_Component Server WMI Class