VCCLCompilerTool.EnablePREfast Property
Gets or sets whether Native Code Analysis is enabled.
Namespace: Microsoft.VisualStudio.VCProjectEngine
Assembly: Microsoft.VisualStudio.VCProjectEngine (in Microsoft.VisualStudio.VCProjectEngine.dll)
Syntax
Property EnablePREfast As Boolean
Dim instance As VCCLCompilerTool
Dim value As Boolean
value = instance.EnablePREfast
instance.EnablePREfast = value
bool EnablePREfast { get; set; }
property bool EnablePREfast {
bool get ();
void set (bool value);
}
function get EnablePREfast () : boolean
function set EnablePREfast (value : boolean)
Property Value
Type: System.Boolean
true to enable code analysis (/analyze).
Remarks
Additional options can be set using the AdditionalOptions property.
Notes
/analyze is only available in Enterprise (Team Developer) versions for x86 compilers.
Examples
The following example demonstrates how to use the EnablePREfast and AdditionalOptions properties to set the /analyze:WX- switch. (Both properties are required to do this.) Specifying /analyze:WX- means that code analysis warnings will not be treated as errors when compiling with /WX. For more information, see /analyze (Enterprise Code Analysis).
To run this example, enter and run this example as outlined in How to: Compile and Run the Automation Object Model Code Examples. Then, in the new instance of Visual Studio, load a Visual C++ project and use the Add-in Manager to activate the add-in.
' Add reference to Microsoft.VisualStudio.VCProjectEngine.
Imports System
Imports EnvDTE
Imports EnvDTE80
Imports System.Diagnostics
Imports Microsoft.VisualStudio.VCProjectEngine
Imports System.Text
Sub EnablePREfastExample(ByVal dte As DTE2)
Dim prj As VCProject
Dim cfgs, tools As IVCCollection
Dim cfg As VCConfiguration
Dim tool As VCCLCompilerTool
Dim sb As New StringBuilder
prj = CType(dte.Solution.Projects.Item(1).Object, _
Microsoft.VisualStudio.VCProjectEngine.VCProject)
cfgs = CType(prj.Configurations, _
Microsoft.VisualStudio.VCProjectEngine.IVCCollection)
cfg = CType(cfgs.Item(1), _
Microsoft.VisualStudio.VCProjectEngine.VCConfiguration)
tool = CType(cfg.Tools("VCCLCompilerTool"), _
Microsoft.VisualStudio.VCProjectEngine.VCCLCompilerTool)
sb.Length = 0
sb.Append("Current project PREfast setting: " _
& tool.EnablePREfast & Environment.NewLine)
sb.Append("Flag: " & tool.AdditionalOptions)
MsgBox(sb.ToString)
' Toggle PREfast setting.
If Not (tool.EnablePREfast = True) Then
' PREfast is not enabled. Turn it and the WX- flag on.
tool.EnablePREfast = True
tool.AdditionalOptions = "/analyze:WX-"
Else
' Toggle the opposite.
tool.EnablePREfast = False
tool.AdditionalOptions = "/analyze:WX"
End If
sb.Length = 0
sb.Append("New project PREfast setting: " _
& tool.EnablePREfast & Environment.NewLine)
sb.Append("Flag: " & tool.AdditionalOptions)
MsgBox(sb.ToString)
End Sub
// Add references to Microsoft.VisualStudio.VCProjectEngine and
// System.Windows.Forms.
using System;
using Extensibility;
using EnvDTE;
using EnvDTE80;
using Microsoft.VisualStudio.VCProjectEngine;
using System.Text;
using System.Windows.Forms;
public void EnablePREfastExample(DTE2 dte)
{
try
{
VCProject prj;
IVCCollection cfgs, tools;
VCConfiguration cfg;
VCCLCompilerTool tool;
StringBuilder sb = new StringBuilder();
prj = (Microsoft.VisualStudio.VCProjectEngine.VCProject)
dte.Solution.Projects.Item(1).Object;
cfgs =
(Microsoft.VisualStudio.VCProjectEngine.IVCCollection)
prj.Configurations;
cfg =
(Microsoft.VisualStudio.VCProjectEngine.VCConfiguration)
cfgs.Item(1);
tools =
(Microsoft.VisualStudio.VCProjectEngine.IVCCollection)
cfg.Tools;
tool =
(Microsoft.VisualStudio.VCProjectEngine.VCCLCompilerTool)
tools.Item("VCCLCompilerTool");
sb.Length = 0;
sb.Append("Current project PREfast setting: " +
tool.EnablePREfast + Environment.NewLine);
sb.Append("Flag: " + tool.AdditionalOptions);
MessageBox.Show(sb.ToString());
// Toggle PREfast setting.
if (!(tool.EnablePREfast == true))
{
// PREfast is not enabled. Turn it and the WX- flag on.
tool.EnablePREfast = true;
tool.AdditionalOptions = "/analyze:WX-";
}
else
{
// Toggle the opposite.
tool.EnablePREfast = false;
tool.AdditionalOptions = "/analyze:WX";
}
sb.Length = 0;
sb.Append("New project PREfast setting: " +
tool.EnablePREfast + Environment.NewLine);
sb.Append("Flag: " + tool.AdditionalOptions);
MessageBox.Show(sb.ToString());
}
catch (System.Exception errmsg)
{
MessageBox.Show("ERROR! " + errmsg.Message);
}
}
Permissions
- Full trust for the immediate caller. This member cannot be used by partially trusted code. For more information, see Using Libraries from Partially Trusted Code.
See Also
Concepts
/analyze (Enterprise Code Analysis)