Walkthrough: Creating COM Objects with Visual Basic
When creating new applications or components, it is best to create .NET Framework assemblies. However, Visual Basic also makes it easy to expose a .NET Framework component to COM. This enables you to provide new components for earlier application suites that require COM components. This walkthrough demonstrates how to use Visual Basic to expose .NET Framework objects as COM objects, both with and without the COM class template.
The easiest way to expose COM objects is by using the COM class template. The COM class template creates a new class, and then configures your project to generate the class and interoperability layer as a COM object and register it with the operating system.
Note
Although you can also expose a class created in Visual Basic as a COM object for unmanaged code to use, it is not a true COM object and cannot be used by Visual Basic. For more information, see COM Interoperability in .NET Framework Applications (Visual Basic).
Note
Your computer might show different names or locations for some of the Visual Studio user interface elements in the following instructions. The Visual Studio edition that you have and the settings that you use determine these elements. For more information, see Customizing Development Settings.
To create a COM object by using the COM class template
Open a new Windows Application project from the File menu by clicking New Project.
In the New Project dialog box under the Project Types field, check that Windows is selected. Select Class Library from the Templates list, and then click OK. The new project is displayed.
Select Add New Item from the Project menu. The Add New Item dialog box is displayed.
Select COM Class from the Templates list, and then click Add. Visual Basic adds a new class and configures the new project for COM interop.
Add code such as properties, methods, and events to the COM class.
Select Build ClassLibrary1 from the Build menu. Visual Basic builds the assembly and registers the COM object with the operating system.
Creating COM Objects without the COM Class Template
You can also create a COM class manually instead of using the COM class template. This procedure is helpful when you are working from the command line or when you want more control over how COM objects are defined.
To set up your project to generate a COM object
Open a new Windows Application project from the File menu by clicking NewProject.
In the New Project dialog box under the Project Types field, check that Windows is selected. Select Class Library from the Templates list, and then click OK. The new project is displayed.
In Solution Explorer, right-click your project, and then click Properties. The Project Designer is displayed.
Click the Compile tab.
Select the Register for COM Interop check box.
To set up the code in your class to create a COM object
In Solution Explorer, double-click Class1.vb to display its code.
Rename the class to ComClass1.
Add the following constants to ComClass1. They will store the Globally Unique Identifier (GUID) constants that the COM objects are required to have.
Public Const ClassId As String = "" Public Const InterfaceId As String = "" Public Const EventsId As String = ""
On the Tools menu, click Create Guid. In the Create GUID dialog box, click Registry Format and then click Copy. Click Exit.
Replace the empty string for the ClassId with the GUID, removing the leading and trailing braces. For example, if the GUID provided by Guidgen is "{2C8B0AEE-02C9-486e-B809-C780A11530FE}" then your code should appear as follows.
Public Const ClassId As String = "2C8B0AEE-02C9-486e-B809-C780A11530FE"
Repeat the previous steps for the InterfaceId and EventsId constants, as in the following example.
Public Const InterfaceId As String = "3D8B5BA4-FB8C-5ff8-8468-11BF6BD5CF91" Public Const EventsId As String = "2B691787-6ED7-401e-90A4-B3B9C0360E31"
Note
Make sure that the GUIDs are new and unique; otherwise, your COM component could conflict with other COM components.
Add the ComClass attribute to ComClass1, specifying the GUIDs for the Class ID, Interface ID, and Events ID as in the following example:
<ComClass(ComClass1.ClassId, ComClass1.InterfaceId, ComClass1.EventsId)> Public Class ComClass1
COM classes must have a parameterless Public Sub New() constructor, or the class will not register correctly. Add a parameterless constructor to the class:
Public Sub New() MyBase.New() End Sub
Add properties, methods, and events to the class, ending it with an End Class statement. Select Build Solution from the Build menu. Visual Basic builds the assembly and registers the COM object with the operating system.
Note
The COM objects you generate with Visual Basic cannot be used by other Visual Basic applications because they are not true COM objects. Attempts to add references to such COM objects will raise an error. For details, see COM Interoperability in .NET Framework Applications (Visual Basic).
See Also
Tasks
Walkthrough: Implementing Inheritance with COM Objects (Visual Basic)
Troubleshooting Interoperability (Visual Basic)
Reference
Other Resources
COM Interoperability in .NET Framework Applications (Visual Basic)