Partager via


SH-4 Assembler Error Messages 200-321 (Windows Embedded CE 6.0)

1/5/2010

The following table shows the SH-4 assembler error messages 200-312.

Message # and Severity Message Text Explanation

200 ERROR

Symbol "%s", first used at %s, is never defined

A symbol was referenced without providing a definition for it. Either define it (using .EQU, a label, and so on), or import it (using .IMPORT or .GLOBAL).

202 ERROR

Illegal symbol "%s"

User-defined symbols are not permitted to begin with \& or . (a period).

203 ERROR

Illegal label symbol "%s"

User defined symbols are not permitted to begin with \& or . (a period).

205 WARN

%s has already been declared %s

A symbol was declared or defined that has already been declared or defined.

206 ERROR

%s has already been declared %s

A symbol was declared or defined that has already been declared or defined.

207 ERROR

Preprocessor symbol "%s" has not been defined yet

A preprocessor symbol was used before defining it.

209 ERROR

Floating point is not valid here

A floating point value was used in an invalid manner.

210 ERROR

A string ("%s") is not valid here

A string constant or a string-valued symbol or expression was used in a context in which strings, including character constants, are not supported.

211 ERROR

Cannot %s a %s symbol (%s)

A symbol that cannot be imported or exported (one defined using .ASSIGN, .ASSIGNA, .ASSIGNC, .REG, or .SECTION, or an internal register symbol) was used in an .EXPORT or .GLOBAL assembler directive.

212 ERROR

Symbol "%s" has not been defined yet

A symbol was referenced in a context where forward references are not permitted, but the symbol has not yet been defined, or its value is not yet known.

213 ERROR

The value of symbol "%s" is not known yet

A symbol was referenced in a context where forward references are not permitted, but the symbol has not yet been defined, or its value is not yet known.

214 ERROR

"%s" is an .IMPORT symbol; its value is unknown

An .IMPORT symbol was used in a context where external references are not permitted.

301 ERROR

Too many operands; expecting %s

Too many operands were supplied for an instruction or an assembler directive.

302 ERROR

"%s" is not an opcode, directive, or macro

An operation name was specified that is not an opcode or directive, nor a defined macro. Check the spelling, or if it is a macro, make sure it has been defined before the first use.

304 ERROR

Not enough operands; expecting %s

Fewer operands were supplied than are required for an instruction or an assembler directive.

307 ERROR

This addressing mode is not legal here

An addressing mode was specified that is not legal for the instruction or the instruction/modifier combination, or a modifier was specified that is not legal for the instruction.

308 ERROR

Invalid addressing mode (incompatible operands)

A combination of addressing modes was specified that is not legal for the instruction or the instruction/modifier combination, or a modifier was specified that is not legal for the combination of addressing modes and the instruction.

309 ERROR

Invalid addressing mode (illegal register %s): "%s"

A register name was specified in a place where that register (or register type) is not legal.

310 ERROR

Cannot use %s here; only r0 is valid

A register other than r0 was specified in a context where only r0 is legal.

311 ERROR

"%s" (%s) is not a register

The symbol specified as the operand of a .REG directive is not a valid register name.

312 ERROR

This would require %s relocation

An operation was attempted that cannot be represented in the MS-COFF object format as currently defined.

314 ERROR

This modifier is not valid for this instruction

This modifier is not valid for this instruction

315 ERROR

Modifier/operand combo invalid for target "%s"

Modifier/operand combo invalid for target "%s"

316 ERROR

This modifier is not valid with these operands

The modifier is not valid

317 ERROR

Operand %d type %s is invalid for this instruction

Operand %d type %s is invalid for this instruction

318 ERROR

Invalid operand types (%s, %s) for this instruction

Invalid operand types (%s, %s) for this instruction

320 ERROR

The first operand must be fr0

The first operand must be the address of floating point register 0.fr0

321 ERROR

Invalid addressing mode "%s"

Invalid addressing mode

See Also

Reference

SH-4 Assembler Error Messages

Other Resources

Renesas SH-4 Series Assembler