HidP_SetScaledUsageValue (Compact 2013)
3/26/2014
This function converts a signed and scaled physical number to a HID usage's logical value and sets the usage value in a specified HID report.
Syntax
NTSTATUS HidP_SetScaledUsageValue(
HIDP_REPORT_TYPE ReportType,
USAGE UsagePage,
USHORT LinkCollection,
USAGE Usage,
LONG UsageValue,
PHIDP_PREPARSED_DATA PreparsedData,
PCHAR Report,
ULONG ReportLength
);
Parameters
- ReportType
[in] HIDP_REPORT_TYPE enumerator value that indicates the type of HID report located at Report.
- UsagePage
[in] Usage page of a usage.
- LinkCollection
[in] Optional. Link collection that contains the usage. If LinkCollection is nonzero, the function only sets the usage, if one exists, in this link collection. If LinkCollection is zero, the function sets the first usage it finds in the top-level collection associated with PreparsedData.
- Usage
[in] Usage.
- UsageValue
[in] Signed and scaled physical number, which the function converts to the logical value of Usage.
- PreparsedData
[in] Pointer to a top-level's preparsed data.
- Report
[in, out] On input, an initialized HID report. On output, a pointer to a HID report.
- ReportLength
[in] Size, in bytes, of the HID report located at Report, which must be equal to the report length for the specified report type that the HidP_GetCaps function returns in a collection's HIDP_CAPS structure.
Return Value
The following table shows the possible return values.
Value |
Description |
---|---|
HIDP_STATUS_SUCCESS |
The function has successfully set the usage value. |
HIDP_STATUS_BAD_LOG_PHY_VALUES |
Usage has an illegal logical or physical range that prevents scaling. |
HIDP_STATUS_VALUE_OUT_OF_RANGE |
Specified physical value is out-of-range and the usage does not have null value. |
HIDP_STATUS_INVALID_REPORT_LENGTH |
Report length is not valid. |
HIDP_STATUS_INVALID_REPORT_TYPE |
Specified report type is not valid. |
HIDP_STATUS_INCOMPATIBLE_REPORT_ID |
Report contains a collection with buttons in the specified usage page, but there are no such usages in the report. |
HIDP_STATUS_INVALID_PREPARSED_DATA |
Preparsed data is not valid. |
HIDP_STATUS_USAGE_NOT_FOUND |
Report contains a requested usage that is not in any report supported by the top-level collection. |
HIDP_STATUS_NULL |
Specified physical value is out-of-range, the usage has a NULL value, and the function has set the NULL value. |
Remarks
The terms button and usage are used synonymously.
HidP_SetScaledUsageValue sets the sign bit.
If the function returns HIDP_STATUS_INCOMPATIBLE_REPORT_ID, the specified report does contain the usage. However, a HID client driver can set the usage in a zero-initialized report.
Requirements
Header |
hidpi.h |
Library |
Hidparse_lib.lib |
See Also
Reference
HID Parser Functions
HIDP_CAPS
HidP_GetCaps
HIDP_REPORT_TYPE
HidP_SetUsageValue