Remote Call Profiler Data Collection Functions
The Remote Call Profiler data collection functions are defined in the Cecap.h file, which you can find in the Sdk\Wce420\Platman\Include directory of the top-level Platman directory for Platform Manager.
The following table shows the Remote Call Profiler data collection functions.
Function | Description |
---|---|
StartProfile | Increments the start/stop counter for the specified profiling level. |
StopProfile | Decrements the start/stop counter for the specified profiling level. |
SuspendProfile | Increments the suspend/resume counter for the specified profiling level. |
ResumeProfile | Decrements the suspend/resume counter for the specified profiling level. |
MarkProfile | Inserts a profile mark into the .icp file. |
CommentMarkProfile | Inserts a profile mark and a user-defined text string into the .icp file. |
CommentMarkAtProfile | Inserts a profile mark, a user-defined text string, and a timestamp value into the .icp file. |
NameProfile | Assigns a name to a specified profiling element. |
See Also
Data Collection Control | Remote Call Profiler Data Collection API Reference
Last updated on Friday, October 08, 2004
© 1992-2003 Microsoft Corporation. All rights reserved.