Msvm_EmulatedEthernetPort class
Represents an emulated Ethernet adapter. This adapter is used when a virtual machine is not capable of running the synthetic Ethernet port when no integrated circuits are installed in the guest.
Note
This class is not available to generation 2 virtual machines.
The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.
Syntax
[Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_EmulatedEthernetPort : CIM_EthernetPort
{
string InstanceID;
string Caption = "Ethernet Port";
string Description = "Microsoft Emulated Ethernet Port";
string ElementName = "Legacy Network Adapter";
datetime InstallDate;
string Name = "Ethernet Port";
uint16 OperationalStatus[] = 2;
string StatusDescriptions[] = "OK";
string Status;
uint16 HealthState = 5;
uint16 CommunicationStatus;
uint16 DetailedStatus;
uint16 OperatingStatus;
uint16 PrimaryStatus;
uint16 EnabledState = 5;
string OtherEnabledState;
uint16 RequestedState = 12;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
uint16 AvailableRequestedStates[];
uint16 TransitioningToState;
string SystemCreationClassName = "Msvm_ComputerSystem";
string SystemName;
string CreationClassName = "Msvm_EmulatedEthernetPort";
string DeviceID = "Microsoft:GUID\device-specific data";
boolean PowerManagementSupported;
uint16 PowerManagementCapabilities[];
uint16 Availability;
uint16 StatusInfo;
uint32 LastErrorCode;
string ErrorDescription;
boolean ErrorCleared;
string OtherIdentifyingInfo[];
uint64 PowerOnHours;
uint16 TotalPowerOnHours;
string IdentifyingDescriptions[];
uint16 AdditionalAvailability[] = 6;
uint64 MaxQuiesceTime;
uint64 Speed = 1000000000;
uint64 MaxSpeed = 1000000000;
uint64 RequestedSpeed = 1000000000;
uint16 UsageRestriction = 4;
uint16 PortType = 1;
string OtherPortType = "Virtual Ethernet";
string OtherNetworkPortType;
uint16 PortNumber;
uint16 LinkTechnology = 2;
string OtherLinkTechnology;
string PermanentAddress;
string NetworkAddresses[];
boolean FullDuplex = True;
boolean AutoSense = True;
string SupportedMaximumTransmissionUnit = 1500;
uint64 ActiveMaximumTransmissionUnit = 1500;
uint32 MaxDataSize = 1500;
uint16 Capabilities[];
string CapabilityDescriptions[];
uint16 EnabledCapabilities[];
string OtherEnabledCapabilities[];
};
Members
The Msvm_EmulatedEthernetPort class has these types of members:
Methods
The Msvm_EmulatedEthernetPort class has these methods.
Method | Description |
---|---|
EnableDevice | This method is not supported. |
OnlineDevice | This method is not supported. |
QuiesceDevice | This method is not supported. |
RequestStateChange | Requests a state change. |
Reset | Resets the emulated device. |
RestoreProperties | This method is not supported. |
SaveProperties | This method is not supported. |
SetPowerState | This method is not supported. |
Properties
The Msvm_EmulatedEthernetPort class has these properties.
-
ActiveMaximumTransmissionUnit
-
-
Data type: uint64
-
Access type: Read-only
The active or negotiated maximum transmission unit (MTU) that can be supported. This property is inherited from CIM_NetworkPort, and it is always set to 1500.
-
-
AdditionalAvailability
-
-
Data type: uint16 array
-
Access type: Read-only
Any additional availability and status of the device, beyond that specified in the Availability property. This property is inherited from CIM_LogicalDevice, and it is always set to 6 ("Not Applicable").
-
-
AutoSense
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the network port is capable of automatically determining the speed or other communications characteristics of the attached network media. This property is inherited from CIM_NetworkPort, and it is always set to True.
-
-
Availability
-
-
Data type: uint16
-
Access type: Read-only
The primary availability and status of the device. This property is inherited from CIM_LogicalDevice, and it is always set to Null.
-
-
AvailableRequestedStates
-
-
Data type: uint16 array
-
Access type: Read-only
Indicates the possible values for the RequestedState parameter of the RequestStateChange method used to initiate a state change. The values listed will be a subset of the values contained in the RequestedStatesSupported property of the associated instance of CIM_EnabledLogicalElementCapabilities, where the values selected are a function of the current state of the CIM_EnabledLogicalElement. This property can be non-Null if an implementation is able to advertise the set of possible values as a function of the current state. This property will be Null if an implementation is unable to determine the set of possible values as a function of the current state.
This property is inherited from CIM_EnabledLogicalElement.
-
Enabled (2)
-
Disabled (3)
-
Shut Down (4)
-
Offline (6)
-
Test (7)
-
Defer (8)
-
Quiesce (9)
-
Reboot (10)
-
Reset (11)
-
DMTF Reserved (.. )
-
-
Capabilities
-
-
Data type: uint16 array
-
Access type: Read-only
Capabilities of the Ethernet port. This property is inherited from CIM_EthernetPort and is not used.
-
-
CapabilityDescriptions
-
-
Data type: string array
-
Access type: Read-only
An array of free-form strings that provides more detailed explanations for any of the Ethernet port features that are indicated in the Capabilities array. Note, each entry of this array is related to the entry in the Capabilities array that is located at the same index. This property is inherited from CIM_EthernetPort and is not used.
-
-
Caption
-
-
Data type: string
-
Access type: Read-only
A short description of the object. This property is inherited from CIM_ManagedElement, and it is always set to "Ethernet Port".
-
-
CommunicationStatus
-
-
Data type: uint16
-
Access type: Read-only
Indicates the ability of the instrumentation to communicate with the underlying managed element. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
-
-
CreationClassName
-
-
Data type: string
-
Access type: Read-only
The name of the class or the subclass used in the creation of an instance. When used with the other key properties of this class, this property allows all instances of this class and its subclasses to be uniquely identified. This property is inherited from CIM_LogicalDevice, and it is always set to "Msvm_EmulatedEthernetPort".
-
-
Description
-
-
Data type: string
-
Access type: Read-only
A description of the object. This property is inherited from CIM_ManagedElement, and it is always set to "Microsoft Emulated Ethernet Port".
-
-
DetailedStatus
-
-
Data type: uint16
-
Access type: Read-only
Complements the PrimaryStatus property with additional status detail. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
-
-
DeviceID
-
-
Data type: string
-
Access type: Read-only
An address or other identifying information used to uniquely name the logical device. This property is inherited from CIM_LogicalDevice, and it is always set to "Microsoft:GUID\device-specific data".
-
-
ElementName
-
-
Data type: string
-
Access type: Read-only
A display name for the object. This property is inherited from CIM_ManagedElement, and it is always set to "Legacy Network Adapter".
-
-
EnabledCapabilities
-
-
Data type: uint16 array
-
Access type: Read-only
The capabilities that are enabled from the list of all supported ones, which are defined in the Capabilities array. This property is inherited from CIM_EthernetPort, but it is not used.
-
-
EnabledDefault
-
-
Data type: uint16
-
Access type: Read-only
An administrator's default or startup configuration for the enabled state of an element. This property is inherited from CIM_EnabledLogicalElement and is always set to 2 ("Enabled").
-
-
EnabledState
-
-
Data type: uint16
-
Access type: Read-only
The enabled and disabled states of an element. This property is inherited from CIM_EnabledLogicalElement, and it is always set to 5 ("Not Applicable").
-
-
ErrorCleared
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the error reported in LastErrorCode is now cleared. This property is inherited from CIM_LogicalDevice and is not used.
-
-
ErrorDescription
-
-
Data type: string
-
Access type: Read-only
A string that provides more information about the error recorded in LastErrorCode, and information on any corrective actions that can be taken. This property is inherited from CIM_LogicalDevice and is not used.
-
-
FullDuplex
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the port is operating in full duplex mode. This property is inherited from CIM_NetworkPort, and it is always set to True.
-
-
HealthState
-
-
Data type: uint16
-
Access type: Read-only
The current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. This property is inherited from CIM_ManagedSystemElement, and it is always set to 5 ("OK").
-
-
IdentifyingDescriptions
-
-
Data type: string array
-
Access type: Read-only
An array of free-form strings that provide explanations and details behind the entries in the OtherIdentifyingInfo array. Each entry of this array is related to the entry in OtherIdentifyingInfo that is located at the same index. This property is inherited from CIM_LogicalDevice and is not used.
-
-
InstallDate
-
-
Data type: datetime
-
Access type: Read-only
A datetime value that indicates when the object was installed. Lack of a value does not indicate that the object is not installed. This property is inherited from CIM_ManagedSystemElement.
-
-
InstanceID
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Key
Uniquely identifies an instance of this class. This property is inherited from CIM_ManagedElement.
-
-
LastErrorCode
-
-
Data type: uint32
-
Access type: Read-only
The last error code reported by the logical device. This property is inherited from CIM_LogicalDevice and is not used.
-
-
LinkTechnology
-
-
Data type: uint16
-
Access type: Read-only
The types of links. When set to 1 ("Other"), the related property OtherLinkTechnology contains a string description of the type of link. This property is inherited from CIM_NetworkPort and is always set to 2 ("Ethernet").
-
-
MaxDataSize
-
-
Data type: uint32
-
Access type: Read-only
The maximum size of the INFO (non-MAC) field that will be received or transmitted. This property is inherited from CIM_EthernetPort, and it is always set to 1500.
-
-
MaxQuiesceTime
-
-
Data type: uint64
-
Access type: Read-only
This property is inherited from CIM_LogicalDevice and is not used.
-
-
MaxSpeed
-
-
Data type: uint64
-
Access type: Read-only
The maximum bandwidth of the port, in bits per second. This property is inherited from CIM_LogicalPort, and it is always set to 1000000000.
-
-
Name
-
-
Data type: string
-
Access type: Read-only
The label by which the object is known. When subclassed, this property can be overridden to be a key property. This property is inherited from CIM_ManagedSystemElement, and it is always set to "Ethernet Port".
-
-
NetworkAddresses
-
-
Data type: string array
-
Access type: Read-only
The Ethernet/802.3 MAC addresses, formatted as twelve hexadecimal digits (for example, "010203040506"), with each pair representing one of the six octets of the MAC address in canonical bit order (the group address bit is found in the low order bit of the first character of the string). This property is inherited from CIM_EthernetPort and is not used.
-
-
OperatingStatus
-
-
Data type: uint16
-
Access type: Read-only
Provides current status information for the operational condition of the element and can be used for providing more detail with respect to the value of the EnabledState property. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
-
-
OperationalStatus
-
-
Data type: uint16 array
-
Access type: Read-only
The current statuses of the element. This property is inherited from CIM_ManagedSystemElement, and it is always set to 2 ("OK").
-
-
OtherEnabledCapabilities
-
-
Data type: string array
-
Access type: Read-only
An array of free-form strings that provides more detailed explanations for any of the enabled capabilities that are specified as "Other". This property is inherited from CIM_EthernetPort and is not used.
-
-
OtherEnabledState
-
-
Data type: string
-
Access type: Read-only
A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 ("Other"). This property must be set to Null when EnabledState is any value other than 1. This property is inherited from CIM_EnabledLogicalElement and is not used.
-
-
OtherIdentifyingInfo
-
-
Data type: string array
-
Access type: Read-only
Any data, in addition to device ID information, that could be used to identify a logical device. For example, you could use this property to hold the operating system's display name for the device. This property is inherited from CIM_LogicalDevice and is not used.
-
-
OtherLinkTechnology
-
-
Data type: string
-
Access type: Read-only
A string value that describes LinkTechnology when it is set to 1 ("Other"). This property is inherited from CIM_NetworkPort, but it is not used.
-
-
OtherNetworkPortType
-
-
Data type: string
-
Access type: Read-only
This property is inherited from CIM_NetworkPort and is set to Null.
-
-
OtherPortType
-
-
Data type: string
-
Access type: Read-only
The type of module, when PortType is set to 1 ("Other"). This property is inherited from CIM_LogicalPort and is always set to "Virtual Ethernet".
-
-
PermanentAddress
-
-
Data type: string
-
Access type: Read-only
The network address that is hardcoded into a port. This address can be changed using a firmware upgrade or a software configuration. When this change is made, the field should be updated at the same time. This should be left blank if no hardcoded address exists for the network adapter. This property is inherited from CIM_NetworkPort.
-
-
PortNumber
-
-
Data type: uint16
-
Access type: Read-only
Network ports are often numbered relative to either a logical module or a network element. This property is inherited from CIM_NetworkPort.
Value Meaning - 0
The NIC is not emulated. - 1
The NIC is emulated. -
-
PortType
-
-
Data type: uint16
-
Access type: Read-only
The specific mode that is currently enabled for the port. When set to 1 ("Other"), the related property OtherPortType contains a string description of the type of port. This property is inherited from CIM_EthernetPort, and it is always set to 1 ("Other").
-
-
PowerManagementCapabilities
-
-
Data type: uint16 array
-
Access type: Read-only
The power management capabilities of the device. This property is inherited from CIM_LogicalDevice and is not used.
-
-
PowerManagementSupported
-
-
Data type: boolean
-
Access type: Read-only
Indicates whether the device can be power managed. This property is inherited from CIM_LogicalDevice and is not used.
-
-
PowerOnHours
-
-
Data type: uint64
-
Access type: Read-only
The number of consecutive hours that this device has been powered, since its last power cycle. This property is inherited from CIM_LogicalDevice and is not used.
-
-
PrimaryStatus
-
-
Data type: uint16
-
Access type: Read-only
Provides high level status information. This property should be used in conjunction with the DetailedStatus property to provide high level and detailed health status information for the element and its subcomponents. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
-
-
RequestedSpeed
-
-
Data type: uint64
-
Access type: Read-only
The requested bandwidth of the port, in bits per second. The actual bandwidth is reported in LogicalPort.Speed. This property is inherited from CIM_LogicalPort, and it is always set to 1000000000.
-
-
RequestedState
-
-
Data type: uint16
-
Access type: Read-only
The last requested or desired state for the management service. When EnabledState is set to 5 ("Not Applicable"), then this property has no meaning. This property is inherited from CIM_EnabledLogicalElement, and it is always set to 12 ("Not Applicable").
-
-
Speed
-
-
Data type: uint64
-
Access type: Read-only
The current bandwidth of the port, in bits per second. For ports that vary in bandwidth or for those where no accurate estimation can be made, this property should contain the nominal bandwidth. This property is inherited from CIM_NetworkPort, and it is always set to 1000000000.
-
-
Status
-
-
Data type: string
-
Access type: Read-only
This property is inherited from CIM_ManagedSystemElement, but it is not used.
-
-
StatusDescriptions
-
-
Data type: string array
-
Access type: Read-only
Strings that describe the various OperationalStatus array values. Entries in this array are correlated with those at the same array index in OperationalStatus. This property is inherited from CIM_ManagedSystemElement, and it is always set to "OK".
-
-
StatusInfo
-
-
Data type: uint16
-
Access type: Read-only
The state of the logical device. This property is inherited from CIM_LogicalDevice and is not used.
-
-
SupportedMaximumTransmissionUnit
-
-
Data type: string
-
Access type: Read-only
-
Qualifiers: Units ("Bytes")
The maximum transmission unit (MTU) that can be supported, in bytes. This property is inherited from CIM_NetworkPort, and it is always set to 1500.
-
-
SystemCreationClassName
-
-
Data type: string
-
Access type: Read-only
The creation class name of the scoping system. This property is inherited from CIM_LogicalDevice, and it is always set to "Msvm_ComputerSystem".
-
-
SystemName
-
-
Data type: string
-
Access type: Read-only
The virtual machine ID in GUID form. This property is inherited from CIM_LogicalDevice.
-
-
TimeOfLastStateChange
-
-
Data type: datetime
-
Access type: Read-only
The date or time when the EnabledState of the element last changed. If the state of the element has not changed and this property is populated, then it must be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property must not be updated. This property is inherited from CIM_EnabledLogicalElement and is not used.
-
-
TotalPowerOnHours
-
-
Data type: uint16
-
Access type: Read-only
The total number of hours that this device has been powered. This property is inherited from CIM_LogicalDevice and is not used.
-
-
TransitioningToState
-
-
Data type: uint16
-
Access type: Read-only
Indicates the target state to which the instance is transitioning. This property is inherited from CIM_EnabledLogicalElement, but it is not used.
-
-
UsageRestriction
-
-
Data type: uint16
-
Access type: Read-only
In some circumstances, a logical port might be identifiable as a front end or back end port. If there is no restriction on the use of the port, then the value should be set to 4 ("Not Restricted"). This property is inherited from CIM_LogicalPort and is always set to 4 ("Not Restricted").
-
Remarks
Access to the Msvm_EmulatedEthernetPort class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.
Examples
See Querying networking objects.
Requirements
Requirement | Value |
---|---|
Minimum supported client |
Windows 8 [desktop apps only] |
Minimum supported server |
Windows Server 2012 [desktop apps only] |
Namespace |
Root\Virtualization\V2 |
MOF |
|
DLL |
|