Editar

Compartilhar via


ConnectionsZone.InstructionText Property

Definition

Gets or set the text that is used for general instructions about the selected control in the section of the connection user interface (UI) for managing existing connections.

public:
 virtual property System::String ^ InstructionText { System::String ^ get(); void set(System::String ^ value); };
public override string InstructionText { get; set; }
member this.InstructionText : string with get, set
Public Overrides Property InstructionText As String

Property Value

A string that contains the instruction text for the connection UI. The default text is a culture-specific string supplied by the .NET Framework.

Examples

The following code example demonstrates the use of the InstructionText property with a ConnectionsZone control. The example contains only the code for the Web page that demonstrates use of the property; for the other two code files needed to run the example, see the Example section of the ConnectionsZone class overview. The code example has four parts:

  • A user control that enables you to switch display modes on the Web page. Obtain this code from the ConnectionsZone class overview.

  • A source file that contains the code for a ZIP Code interface, and two WebPart controls acting as the provider and the consumer for a connection. Obtain this code from the ConnectionsZone class overview.

  • A Web page that hosts all the controls, declares an <asp:connectionszone> element, and shows how to use the property programmatically.

  • An explanation of how the example works in a browser.

The Web page declares an <asp:connectionszone> element and, in the Page_PreRender method, the code assigns a value to the InstructionText property.

<%@ Page Language="C#" %>
<%@ register tagprefix="uc1" 
    tagname="DisplayModeMenuCS"
    src="~/displaymodemenucs.ascx" %>
<%@ Register TagPrefix="aspSample" 
    Namespace="Samples.AspNet.CS.Controls" %>

<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" 
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">

<script runat="server">

  protected void Page_PreRender(object sender, EventArgs e)
  {
     // Set properties on verbs.
     connectionsZone1.CancelVerb.Description = 
       "Terminates the connection process";
     connectionsZone1.CloseVerb.Description = 
       "Closes the connections UI";
     connectionsZone1.ConfigureVerb.Description =
       "Configure the transformer for the connection";
     connectionsZone1.ConnectVerb.Description =
       "Connect two WebPart controls";
     connectionsZone1.DisconnectVerb.Description =
       "End the connection between two controls";
    
     // Set properties for UI text strings.
     connectionsZone1.ConfigureConnectionTitle = 
       "Configure";
     connectionsZone1.ConnectToConsumerInstructionText = 
       "Choose a consumer connection point";
     connectionsZone1.ConnectToConsumerText = 
       "Select a consumer for the provider to connect with";
     connectionsZone1.ConnectToConsumerTitle = 
       "Send data to this consumer";
     connectionsZone1.ConnectToProviderInstructionText =
       "Choose a provider connection point";
     connectionsZone1.ConnectToProviderText =
       "Select a provider for the consumer to connect with";
     connectionsZone1.ConnectToProviderTitle =
       "Get data from this provider";
     connectionsZone1.ConsumersInstructionText = 
       "WebPart controls that receive data from providers";
     connectionsZone1.ConsumersTitle = "Consumer Controls";
     connectionsZone1.GetFromText = "Receive from";
     connectionsZone1.GetText = "Retrieve";
     connectionsZone1.HeaderText = 
      "Create and Manage Connections";
     connectionsZone1.InstructionText = 
      "Manage connections for the selected WebPart control";
     connectionsZone1.InstructionTitle = 
       "Manage connections for consumers or providers";
     connectionsZone1.NoExistingConnectionInstructionText = 
       "No connections exist. Click the above link to create "
       + "a connection.";
     connectionsZone1.NoExistingConnectionTitle = 
       "No current connections";
     connectionsZone1.ProvidersInstructionText =
       "WebPart controls that send data to consumers";
     connectionsZone1.ProvidersTitle = "Provider controls";
     
  }
</script>

<html xmlns="http://www.w3.org/1999/xhtml" >
<head runat="server">
    <title>Connection Zone Sample</title>
</head>
<body>
  <form id="form1" runat="server">
  <asp:webpartmanager runat="server" id="mgr">
    <staticconnections>
      <asp:webpartconnection id="connection1" 
        consumerconnectionpointid="ZipCodeConsumer"
        consumerid="zipConsumer"
        providerconnectionpointid="ZipCodeProvider" 
        providerid="zipProvider" />
    </staticconnections>
  </asp:webpartmanager>
  <uc1:displaymodemenucs id="menu1" runat="server" />
  <div>
  <asp:webpartzone id="WebPartZone1" runat="server">
    <zonetemplate>
      <aspsample:zipcodewebpart id="zipProvider" runat="server" 
        Title="Zip Code Provider"  />
      <aspsample:weatherwebpart id="zipConsumer" runat="server" 
        Title="Zip Code Consumer" />
    </zonetemplate>
  </asp:webpartzone>
  <asp:connectionszone id="connectionsZone1" runat="server" >
    <cancelverb text="Terminate" />
    <closeverb text="Close Zone" />
    <configureverb text="Configure" />
    <connectverb text="Connect Controls" />
    <disconnectverb text="End Connection" />
  </asp:connectionszone>
  </div>
  </form>
</body>
</html>
<%@ Page Language="VB" %>
<%@ register tagprefix="uc1" 
    tagname="DisplayModeMenuVB"
    src="~/displaymodemenuvb.ascx" %>
<%@ Register TagPrefix="aspSample" 
    Namespace="Samples.AspNet.VB.Controls" %>

<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" 
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">

<script runat="server">

  Protected Sub Page_PreRender(ByVal sender As Object, _
    ByVal e As System.EventArgs)
    
    ' Set properties for verbs.
    connectionsZone1.CancelVerb.Description = _
      "Terminates the connection process"
    connectionsZone1.CloseVerb.Description = _
      "Closes the connections UI"
    connectionsZone1.ConfigureVerb.Description = _
      "Configure the transformer for the connection"
    connectionsZone1.ConnectVerb.Description = _
      "Connect two WebPart controls"
    connectionsZone1.DisconnectVerb.Description = _
      "End the connection between two controls"
    
    ' Set properties for UI text strings.
    connectionsZone1.ConfigureConnectionTitle = _
      "Configure a new connection"
    connectionsZone1.ConnectToConsumerInstructionText = _
      "Choose a consumer connection point"
    connectionsZone1.ConnectToConsumerText = _
      "Select a consumer for the provider to connect with"
    connectionsZone1.ConnectToConsumerTitle = _
      "Send data to this consumer"
    connectionsZone1.ConnectToProviderInstructionText = _
      "Choose a provider connection point"
    connectionsZone1.ConnectToProviderText = _
      "Select a provider for the consumer to connect with"
    connectionsZone1.ConnectToProviderTitle = _
      "Get data from this provider"
    connectionsZone1.ConsumersInstructionText = _
      "WebPart controls that receive data from providers"
    connectionsZone1.ConsumersTitle = "Consumer Controls"
    connectionsZone1.GetFromText = "Receive from"
    connectionsZone1.GetText = "Retrieve"
    connectionsZone1.HeaderText = _
      "Create and Manage Connections"
    connectionsZone1.InstructionText = _
      "Manage connections for the selected WebPart control"
    connectionsZone1.InstructionTitle = _
      "Manage connections for consumers or providers"
    connectionsZone1.NoExistingConnectionInstructionText = _
      "No connections exist. Click the above link to create " _
      & "a connection."
    connectionsZone1.NoExistingConnectionTitle = _
      "No current connections"
    connectionsZone1.ProvidersInstructionText = _
      "WebPart controls that send data to consumers"
    connectionsZone1.ProvidersTitle = "Provider controls"

  End Sub

</script>

<html xmlns="http://www.w3.org/1999/xhtml" >
<head runat="server">
    <title>Connection Zone Sample</title>
</head>
<body>
  <form id="form1" runat="server">
  <asp:webpartmanager runat="server" id="mgr">
    <staticconnections>
      <asp:webpartconnection id="connection1" 
        consumerconnectionpointid="ZipCodeConsumer"
        consumerid="zipConsumer"
        providerconnectionpointid="ZipCodeProvider" 
        providerid="zipProvider" />
    </staticconnections>
  </asp:webpartmanager>
  <uc1:displaymodemenuvb id="menu1" runat="server" />
  <div>
  <asp:webpartzone id="WebPartZone1" runat="server">
    <zonetemplate>
      <aspsample:zipcodewebpart id="zipProvider" runat="server" 
        Title="Zip Code Provider" />
      <aspsample:weatherwebpart id="zipConsumer" runat="server" 
        Title="Zip Code Consumer" />
    </zonetemplate>
  </asp:webpartzone>
  <asp:connectionszone id="connectionsZone1" runat="server" >
    <cancelverb text="Terminate" />
    <closeverb text="Close Zone" />
    <configureverb text="Configure" />
    <connectverb text="Connect Controls" />
    <disconnectverb text="End Connection" />
  </asp:connectionszone>
  </div>
  </form>
</body>
</html>

Load the page in a browser. Switch to connect mode, using the Display Mode control. Click the verbs menu arrow on the ZIP Code Consumer control, and click the connect verb. In the view that opens for the existing connection, note that the instruction text near the top of the connections zone is the value assigned to the InstructionText property in the code example.

Remarks

The text contained in the InstructionText property is visible whenever the connection UI is displayed and a connection already exists. Just below the header text (contained in the HeaderText property), which is found at the top of the connection UI, is the instruction title, and just below that is the instruction text. The instruction text informs users what type of action can be performed on the currently selected WebPart control (the selected control is the one for which the user clicked a connect verb on the control's verbs menu). By default, the instruction text is Manage the connections for the current Web part.

This property overrides the base InstructionText property from the ToolZone class, so that the default connections zone instruction text can be assigned to the property.

You can set the value of this property declaratively within the opening tag of the <asp:connectionszone> element, by adding an attribute named InstructionText and assigning it a value. You can also set the property value programmatically.

Applies to

See also